commit | 93dc2c8e7c710fd65d269ef0bf684fb7a433a602 | [log] [tgz] |
---|---|---|
author | Cheng C Yang <cheng.c.yang@linux.intel.com> | Fri Apr 12 11:45:31 2019 +0800 |
committer | Cheng C Yang <cheng.c.yang@linux.intel.com> | Fri Apr 12 11:45:31 2019 +0800 |
tree | 5b0397c001773184d36089bec35c612fc7b969a1 | |
parent | d2543f81f4dd7a1f3a0989ec5829401d1147674c [diff] |
Enable PSUSensor support Add psusensor service to enable PSUSensor. Tested By: After BMC started, run ipmitool sensor list, all PSU sensors can show correct name and value. Signed-off-by: Cheng C Yang <cheng.c.yang@linux.intel.com> Change-Id: I55d52c3cc71243a1db10a47551872b458ad9d21b
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access