commit | 31ec7dbb6ae668b4c7bb4f9d630f80253b23f0d8 | [log] [tgz] |
---|---|---|
author | Matt Spinler <spinler@us.ibm.com> | Mon Apr 11 16:49:40 2022 -0500 |
committer | Ed Tanous <ed@tanous.net> | Wed Apr 13 18:28:23 2022 +0000 |
tree | 391e574eba74cc2568821639308f4f3d1f4d2b19 | |
parent | fefdbe7f5124c00a9b05c2c2bad9d560692f7025 [diff] |
Revert "hwmon-temp-sensor: Support sensor with missing labels" It turns out this commit results in ignoring the humidity/pressure sensor for IIO devices that provide both temperature and a different type. It happens because the same device has multiple entries in the 'paths' variable since they are added here: findFiles(root, R"(in_temp\d*_(input|raw))", paths); findFiles(root, R"(in_pressure\d*_(input|raw))", paths); findFiles(root, R"(in_humidityrelative\d*_(input|raw))", paths); and then this change would remove the config entry for the device before it could process the other paths. This reverts commit 0f580944e22534c8814634d76bd752a5d4236f60. Change-Id: I22b4336101fae7782c650b9cf5f515dbbdacca9e Signed-off-by: Matt Spinler <spinler@us.ibm.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access