Fix D-Bus introspect timeout error in cpusensor This commit moves the requesting bus name code to just before calling of io->run to avoid phosphor->mapper introspect failure. Tested: CPU sensors exposed well. Change-Id: I41a8ebddee7e7a1e18dc223e4ff0c170a5c29264 Signed-off-by: Jae Hyun Yoo <jae.hyun.yoo@linux.intel.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access