commit | 74ddf8678b6f1ec858b87de2cc889859fb1113cb | [log] [tgz] |
---|---|---|
author | Qiang XU <qiang.xu@linux.intel.com> | Thu Sep 12 17:12:13 2019 +0800 |
committer | James Feist <james.feist@linux.intel.com> | Fri Sep 20 16:01:11 2019 +0000 |
tree | c0833ce53c573e12dbac63bff6bf1bc655872069 | |
parent | c71c119d227199f017bdc650da55a994c8cb56e1 [diff] |
Add user friendly info in lan leash event log Read NIC info defined in configuration and append to lan leash event log Tested: Unplug network cable of dedicate NIC Check the below log message in https://$bmcip/redfish/v1/Systems/system/LogServices/EventLog/Entries "Message": "Physical Security: eth0(Dedicated Management NIC) LAN leash lost" Change-Id: I9fa1984dc4d830fcd91ba9ef78415d75be6389b3 Signed-off-by: Qiang XU <qiang.xu@linux.intel.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access