commit | 7d6b77d083ac562db423cfe593710c96b005e116 | [log] [tgz] |
---|---|---|
author | Khang Kieu <khangk@google.com> | Thu Feb 10 10:43:36 2022 +0000 |
committer | Ed Tanous <ed@tanous.net> | Wed Feb 16 03:16:26 2022 +0000 |
tree | 88741a56680ee33a66d9b40911d1507ab97f5f53 | |
parent | 73030639a5ba8adfc9d8e54ef66746c95e8958a7 [diff] |
sensors: Fix typo in PSUSensorMain ISL69225 Fixed the typo in this review https://gerrit.openbmc-project.xyz/c/openbmc/dbus-sensors/+/51074 for mistaking ISL'69225' for '68225' Tested: sensor list shows ISL69225 in PSUSensor Signed-off-by: Khang Kieu <khangk@google.com> Change-Id: I2fafd524f9f5ab8e481290cb2325d40717a87822
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access