IpmbSensor:Fix SMBus configuration for VR Temp.

The SMBus index configuration for VR Temp sensor is different
for some platforms.
Hence, SMBus index in which these sensors are connected
is made as D-Bus property, read from xx_baseboard.json file.
Also, sensor read request commands modified to use this value.

Tested :
   1.Dediprog and redfish flash the different platforms,
     with[SMBus index read from json file] and
     without[default SMBus index =3] this configuration change.
    - System up and running.
    - VR Temp sensor and other sensor readings shows
      correctly in 'ipmitool sensor list' output.

Signed-off-by: Anoop S <anoopx.s@intel.com>
Change-Id: Ia106f1c699f5f1515c90585309a65ede37906f18
2 files changed
tree: f261e26cbc0b1d084dff9385e8ffb1c9640a32e3
  1. cmake/
  2. include/
  3. service_files/
  4. src/
  5. tests/
  6. .clang-format
  7. .clang-ignore
  8. .gitignore
  9. cmake-format.json
  10. CMakeLists.txt
  11. Jenkinsfile
  12. LICENSE
  13. MAINTAINERS
  14. README.md
README.md

dbus-sensors

dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.

key features

  • runtime re-configurable from d-bus (entity-manager or the like)

  • isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible

  • async single-threaded: uses sdbusplus/asio bindings

  • multiple data inputs: hwmon, d-bus, direct driver access