Log physical security event of lan leash

Log event of lan link status change by processing dbus signal sent by
networkd in systemd.

Tested:
Unplug network cable of dedicate NIC
Check the below log message in
https://$bmcip/redfish/v1/Systems/system/LogServices/EventLog/Entries
"Message": "Physical Security: eth0 LAN leash lost is asserted"

Change-Id: I16cf41a93896355aa28aaeb07cb16bc788b1abf1
Signed-off-by: Qiang XU <qiang.xu@linux.intel.com>
1 file changed
tree: 004a1026e961de130cfeecba3f334e14882fdcfa
  1. cmake/
  2. include/
  3. service_files/
  4. src/
  5. tests/
  6. .clang-format
  7. .clang-ignore
  8. .gitignore
  9. cmake-format.json
  10. CMakeLists.txt
  11. Jenkinsfile
  12. LICENSE
  13. MAINTAINERS
  14. README.md
README.md

dbus-sensors

dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.

key features

  • runtime re-configurable from d-bus (entity-manager or the like)

  • isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible

  • async single-threaded: uses sdbusplus/asio bindings

  • multiple data inputs: hwmon, d-bus, direct driver access