commit | 8b3f7d401422b8428672e9a664e71b265919a093 | [log] [tgz] |
---|---|---|
author | Alex Qiu <xqiu@google.com> | Mon Jan 06 13:54:42 2020 -0800 |
committer | Alex Qiu <xqiu@google.com> | Tue Jan 07 19:36:41 2020 +0000 |
tree | 8d35e36b28e10d13a3ac39d7595fc243e1f1a524 | |
parent | 347dd4e7a0a4923583151e4d9eb483b65dba9e7b [diff] |
HwmonTemp: Support more than 2 temperature readings; add support for MAX31730. Tested: All 4 temperature readings of MAX31730 are available in IPMI sensors: ~ # ipmitool sensor list | grep xxx xxx_1 | 28.000 | degrees C | ok | na... xxx_2 | 27.000 | degrees C | ok | na... xxx_3 | 29.000 | degrees C | ok | na... xxx_4 | 42.000 | degrees C | ok | na... Signed-off-by: Alex Qiu <xqiu@google.com> Change-Id: I5325dfcc2c7ee8c2737c05e46560153301b206a5
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access