psusensor: Add power state for label In the bytedance system, the vout of a psusensor is related to powerstate, but the temp of this psusensor has nothing to do with powerstate, so a label like: " vout1_PowerState" is needed to mark that vout is related to powerstate, but does not affect the temp of this psusensor Tested: Run`ipmitool power off&&ipmitool sensor list` the vout is na, but temp is correct. Signed-off-by: Lotus Xu <xuxiaohan@bytedance.com> Change-Id: I3fb17a10cffcd7fb46faa11a45582a6c00eabdfa
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access