Add chassis and inventory associations to PSU Pwm

PSU pwm sensors are not associated with chassis base
board object path. This causes the PSU pwm sensors
not list under chassis redfish object. Added chassis
base board path and inventory object path associations
to PSU Pwm Sensors.

Tested:
Get on redfish chassis/<chassis id>/Thermal and
chassis/<chassis id>/sensors  redfish URI shows
PSU Pwm sensors.

Change-Id: Ia862ecff058ca43fee38a6f71bdd57f8c135aae2
Signed-off-by: AppaRao Puli <apparao.puli@linux.intel.com>
4 files changed
tree: 543168fea5c709c434a770a7db74b320f212836a
  1. cmake/
  2. include/
  3. service_files/
  4. src/
  5. tests/
  6. .clang-format
  7. .clang-ignore
  8. .gitignore
  9. cmake-format.json
  10. CMakeLists.txt
  11. Jenkinsfile
  12. LICENSE
  13. MAINTAINERS
  14. README.md
README.md

dbus-sensors

dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.

key features

  • runtime re-configurable from d-bus (entity-manager or the like)

  • isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible

  • async single-threaded: uses sdbusplus/asio bindings

  • multiple data inputs: hwmon, d-bus, direct driver access