Fix PSU PWM fan control 105a19754f003956def5934612b1de86225a4bc1 broke the control interface range as the interface is supposed to accept 0-255 fix it. Tested: PSU PID control worked again Change-Id: I89c03c3382b221256353cc28b1f182c80a063249 Signed-off-by: James Feist <james.feist@linux.intel.com>
dbus-sensors is a collection of sensor applications that provide the xyz.openbmc_project.Sensor collection of interfaces. They read sensor values from hwmon, d-bus, or direct driver access to provide readings. Some advance non-sensor features such as fan presence, pwm control, and automatic cpu detection (x86) are also supported.
runtime re-configurable from d-bus (entity-manager or the like)
isolated: each sensor type is isolated into its own daemon, so a bug in one sensor is unlikely to affect another, and single sensor modifications are possible
async single-threaded: uses sdbusplus/asio bindings
multiple data inputs: hwmon, d-bus, direct driver access