This document describes the host-management interfaces of the OpenBMC object structure, accessible over REST.
The system inventory structure is under the /org/openbmc/inventory
hierarchy.
In OpenBMC the inventory is represented as a path which is hierarchical to the physical system topology. Items in the inventory are referred to as inventory items and are not necessarily FRUs. If the system contains one chassis, a motherboard, and a CPU on the motherboard, then the path to that inventory item would be:
inventory/system/chassis0/motherboard0/cpu0
The properties associated with an inventory item are specific to that item with the addition of these common properties:
version
: a code version associated with this itemfault
: indicates whether this item has reported an error condition (True/False)present
: indicates whether this item is present in the system (True/False)The usual list
and enumerate
REST queries allow the system inventory structure to be accessed. For example, to enumerate all inventory items and their properties:
curl -b cjar -k https://bmc/org/openbmc/inventory/enumerate
To list the properties of one item:
curl -b cjar -k https://bmc/org/openbmc/inventory/system/chassis/motherboard
The system inventory structure is under the /org/openbmc/sensors
hierarchy.
This interface allows monitoring of system attributes like temperature or altitude, and are represented similar to the inventory, by object paths under the top-level sensors
object name. The path categorizes the sensor and shows what the sensor represents, but does not necessarily represent the physical topology of the system.
For example, all temperature sensors are under sensors/temperature
. CPU temperature sensors would be sensors/temperature/cpu[n]
.
These are the common properties associated all sensors:
value
: current value of sensorunits
: units of valuewarning_upper
& warning_lower
: upper & lower threshold for a warning errorcritical_upper
& critical_lower
: upper & lower threshold for a critical errorthreshold_state
: current threshold state (normal, warning, critical)worst_threshold_state
: highest threshold state seen for all time. There is a REST call to reset this state to normal.Unlike IPMI, there are no "functional" sensors in OpenBMC; functional states are represented in the inventory.
To enumerate all sensors in the system:
curl -c cjar -k https://bmc/org/openbmc/sensors/enumerate
List properties of one inventory item:
curl -c cjar -k https://bmc/org/openbmc/sensors/temperature/ambient
The event log structure is under the /org/openbmc/records/events
hierarchy. Each event is a separate object under this structure, referenced by number.
BMC and host firmware on POWER-based servers can report logs to the BMC. Typically, these logs are reported in cases where host firmware cannot start the OS, or cannot reliably log to the OS.
The properties associated with an error log are as follows:
Association
: a uri to the failing inventory partMessage
: An English text string indicating the failureReported By
: Firmware region that created the log ('Host', 'BMC')Severity
: level of problem (Info, Predictive Error, etc)Development Data
: Data dump for use by Development to analyze the failureTo list all reported events:
$ curl -b cjar -k https://bmc/org/openbmc/records/events/ { "data": [ "/org/openbmc/records/events/1", "/org/openbmc/records/events/2", "/org/openbmc/records/events/3", ], "message": "200 OK", "status": "ok" }
To read a specific event log:
$ curl -b cjar -k https://bmc/org/openbmc/records/events/1 { "data": { "association": "/org/openbmc/inventory/system/systemevent", "debug_data": [ ... ], "message": "A systemevent has experienced a unrecoverable error", "reported_by": "Host", "severity": "unrecoverable error", "time": "2016:05:04 01:43:57" }, "message": "200 OK", "status": "ok" }
To delete an event log (log 1 in his example), call the delete
method on the event:
curl -b cjar -k -H "Content-Type: application/json" -X POST \ -d '{"data" : []}' \ https://bmc/org/openbmc/records/events/1/action/delete
To clear all logs, call the top-level clear
method:
curl -b cjar -k -H "Content-Type: application/json" -X POST \ -d '{"data" : []}' \ https://bmc/org/openbmc/records/events/action/clear
With OpenBMC, the BIOS boot options are stored as dbus properties under the settings/host0
path, in the boot_flags
property. Their format adheres to the Boot Options Parameters table specified in the IPMI Specification Document, section 28.13.
Each boot parameter is represented by an individual property, and their hex value is displayed in a string format. For example, a boot flags parameter value of 0x8014000000
would be stored as a 8014000000
string in the settings/host0/boot_flags
property.
The host can be controlled through the chassis
object. It implements a number of actions including powerOn and powerOff. These correspond to the IPMI chassis power on
and chassis power off
commands.
Assuming you have logged in, the following will issue a POST with an empty data payload that powers the host on:
curl -c cjar -b cjar -k -H "Content-Type: application/json" -X POST \ -d '{"data": []}' https://bmc/org/openbmc/control/chassis0/action/powerOn
Other actions available are:
setIdentify
/ clearIdentify
powerOff
softPowerOff
reboot
softReboot
getPowerState