Do tmpl substitutions using all properties on path

The current code would substitute the template arguments in the JSON
files, such as $bus, by only looking at the properties of the interface
that passed the probe.

This commit will try to find a substitution using the properties of all
of the interfaces on the same object path as the interface that passed
the probe.  It does this by reading and storing the properties of all
interfaces that came back from the existing GetSubTree call that finds
the paths of the probed interfaces, instead of just limiting it to the
interfaces that were probed.  The template substitutions are then tried
on the properties of all interfaces until one is successful.

This change is being made so that the interface used in the probe
doesn't also need to contain properties for the device details, such as
the bus property, that otherwise wouldn't belong there.  For example,
the com.ibm.ipzvpd.VINI interface, which models EEPROM contents, is
currently used in probes on IBM systems, and with this change the bus
and address properties can now be on a separate interface, such as the
recently proposed xyz.openbmc_project.Inventory.Decorator.I2CDevice.

Tested:  Tested that the $bus template can be successfully filled in
with the Bus property from an interface other than the one the probe was
matched on.

Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: Ic6f1539b38f6a4098f131d7f14cad6b6ddff041f
4 files changed
tree: 5069410cbd8d18ce71d6f5133027a29b886ba7f1
  1. configurations/
  2. docs/
  3. include/
  4. schemas/
  5. scripts/
  6. service_files/
  7. src/
  8. subprojects/
  9. test/
  10. .clang-format
  11. .clang-ignore
  12. .gitignore
  13. blacklist.json
  14. CONFIG_FORMAT.md
  15. Doxyfile
  16. LICENCE
  17. MAINTAINERS
  18. meson.build
  19. meson_options.txt
  20. README.md
README.md

Entity Manager

Entity manager is a design for managing physical system components, and mapping them to software resources within the BMC. Said resources are designed to allow the flexible adjustment of the system at runtime, as well as the reduction in the number of independent system configurations one needs to create.

Definitions

Entity

A server component that is physically separate, detectable through some means, and can be added or removed from a given OpenBMC system. Said component can, and likely does contain multiple sub-components, but the component itself as a whole is referred to as an entity.

Note, this term is needed because most other terms that could've been used (Component, Field Replaceable Unit, or Assembly) are already overloaded in the industry, and have a distinct definition already, which is a subset of what an entity encompasses.

Exposes

A particular feature of an Entity. An Entity generally will have multiple Exposes records for the various features that component supports. Some examples of features include, LM75 sensors, PID control parameters, or CPU information.

Probe

A set of rules for detecting a given entity. Said rules generally take the form of a D-Bus interface definition.

Goals

Entity manager has the following goals (unless you can think of better ones):

  1. Minimize the time and debugging required to "port" OpenBMC to new systems
  2. Reduce the amount of code that is different between platforms
  3. Create system level maintainability in the long term, across hundreds of platforms and components, such that components interoperate as much as physically possible.

Implementation

A full BMC setup using Entity Manager consists of a few parts:

  1. A detection daemon This is something that can be used to detect components at runtime. The most common of these, fru-device, is included in the Entity-Manager repo, and scans all available I2C buses for IPMI FRU EEPROM devices. Other examples of detection daemons include: peci-pcie: A daemon that utilizes the CPU bus to read in a list of PCIe devices from the processor. smbios-mdr: A daemon that utilizes the x86 SMBIOS table specification to detect the available systems dependencies from BIOS.

    In many cases, the existing detection daemons are sufficient for a single system, but in cases where there is a superseding inventory control system in place (such as in a large datacenter) they can be replaced with application specific daemons that speak the protocol information of their controller, and expose the inventory information, such that failing devices can be detected more readily, and system configurations can be "verified" rather than detected.

  2. An entity manager configuration file Entity manager configuration files are located in the ./configurations directory in the entity manager repository, and include one file per device supported. Entities are detected based on the "Probe" key in the json file. The intention is that this folder contains all hardware configurations that OpenBMC supports, to allows an easy answer to "Is X device supported". An EM configuration contains a number of Exposes records that specify the specific features that this Entity supports. Once a component is detected, entity manager will publish these Exposes records to D-Bus.

  3. A reactor The reactors are things that take the entity manager configurations, and use them to execute and enable the features that they describe. One example of this is dbus-sensors, which contains a suite of applications that input the Exposes records for sensor devices, then connect to the filesystem to create the sensors and scan loops to scan sensors for those devices. Other examples of reactors could include: CPU management daemons and Hot swap backplane management daemons, or drive daemons.

note: In some cases, a given daemon could be both a detection daemon and a reactor when architectures are multi-tiered. An example of this might include a hot swap backplane daemon, which both reacts to the hot swap being detected, and also creates detection records of what drives are present.

Requirements

  1. Entity manager shall support the dynamic discovery of hardware at runtime, using inventory interfaces. The types of devices include, but are not limited to hard drives, hot swap backplanes, baseboards, power supplies, CPUs, and PCIe Add-in-cards.

  2. Entity manager shall support the ability to add or remove support for particular devices in a given binary image. By default, entity manager will support all available and known working devices for all platforms.

  3. Entity manager shall provide data to D-Bus about a particular device such that other daemons can create instances of the features being exposed.

  4. Entity manager shall support multiple detection runs, and shall do the minimal number of changes necessary when new components are detected or no longer detected. Some examples of re-detection events might include host power on, drive plug/unplug, PSU plug/unplug.

  5. Entity manager shall have exactly one configuration file per supported device model. In some cases this will cause duplicated information between files, but the ability to list and see all supported device models in a single place, as well as maintenance when devices do differ in the future is determined to be more important than duplication of configuration files.

Explicitly out of scope

  1. Entity manager shall not directly participate in the detection of devices, and instead will rely on other D-Bus applications to publish interfaces that can be detected.
  2. Entity manager shall not directly participate in management of any specific device. This is requirement is intended to intentionally limit the size and feature set of entity manager, to ensure it remains small, and effective to all users.

Entity Manager Compatible Software

bmcweb A webserver implementation that uses the inventory information from entity-manager to produce a Redfish compliant REST API. intel-ipmi-oem An implementation of the IPMI SDR, FRU, and Storage commands that utilize Entity Manager as the source of information.