configurations: santabarbara: Correct the NIC current sensor mapping
Correct backend NIC and current sensor mapping caused by wrong netname
numbering in schematic.
Change-Id: I0b5ec43625ac146f1195c901a5f2d5c6501260db
Signed-off-by: Fred Chen <Fred.Chen@quantatw.com>
diff --git a/configurations/meta/santabarbara/santabarbara_pcie_switch_board.json b/configurations/meta/santabarbara/santabarbara_pcie_switch_board.json
index 7e58779..9aa3580 100644
--- a/configurations/meta/santabarbara/santabarbara_pcie_switch_board.json
+++ b/configurations/meta/santabarbara/santabarbara_pcie_switch_board.json
@@ -141,7 +141,7 @@
"curr1",
"power1"
],
- "Name": "SWB_P12V_NIC2",
+ "Name": "SWB_P12V_NIC3",
"Thresholds": [
{
"Direction": "greater than",
@@ -173,11 +173,11 @@
}
],
"Type": "INA230",
- "curr1_Name": "SWB_P12V_NIC2_CURR_A",
+ "curr1_Name": "SWB_P12V_NIC3_CURR_A",
"curr1_Offset": 0.0015,
"curr1_Scale": 1111.975981319,
- "in1_Name": "SWB_P12V_NIC2_VOLT_V",
- "power1_Name": "SWB_P12V_NIC2_PWR_W",
+ "in1_Name": "SWB_P12V_NIC3_VOLT_V",
+ "power1_Name": "SWB_P12V_NIC3_PWR_W",
"power1_Offset": 0.0381,
"power1_Scale": 1124985.937676
},
@@ -285,7 +285,7 @@
"curr1",
"power1"
],
- "Name": "SWB_P12V_NIC3",
+ "Name": "SWB_P12V_NIC2",
"Thresholds": [
{
"Direction": "greater than",
@@ -317,11 +317,11 @@
}
],
"Type": "INA230",
- "curr1_Name": "SWB_P12V_NIC3_CURR_A",
+ "curr1_Name": "SWB_P12V_NIC2_CURR_A",
"curr1_Offset": 0.0002,
"curr1_Scale": 1171.920778155,
- "in1_Name": "SWB_P12V_NIC3_VOLT_V",
- "power1_Name": "SWB_P12V_NIC3_PWR_W",
+ "in1_Name": "SWB_P12V_NIC2_VOLT_V",
+ "power1_Name": "SWB_P12V_NIC2_PWR_W",
"power1_Offset": 0.0226,
"power1_Scale": 1186521.120076
},