ADC Scale factor update for FBTP
Updated scale factor for all ADC sensors based on calculation
R2/(R1+R2) in Facebook Tiogapass configuration.
Tested with dbus sensors and see expected values.
Change-Id: I4e36dae55705b050dd48489c762e4be10a338298
Signed-off-by: Vijay Khemka <vijaykhemka@fb.com>
diff --git a/configurations/FBTP.json b/configurations/FBTP.json
index e710421..24d2276 100644
--- a/configurations/FBTP.json
+++ b/configurations/FBTP.json
@@ -3,7 +3,7 @@
{
"Index": 0,
"Name": " MB_P3V3",
- "ScaleFactor": 0.1124,
+ "ScaleFactor": 0.4107,
"Thresholds": [
{
"Direction": "greater than",
@@ -23,7 +23,7 @@
{
"Index": 1,
"Name": " MB_P5V",
- "ScaleFactor": 0.1124,
+ "ScaleFactor": 0.2717,
"Thresholds": [
{
"Direction": "greater than",
@@ -63,7 +63,6 @@
{
"Index": 3,
"Name": " MB_P1V05",
- "ScaleFactor": 0.1124,
"Thresholds": [
{
"Direction": "greater than",
@@ -83,7 +82,6 @@
{
"Index": 4,
"Name": " MB_PVNN_PCH_STBY",
- "ScaleFactor": 0.1124,
"Thresholds": [
{
"Direction": "greater than",
@@ -103,7 +101,7 @@
{
"Index": 5,
"Name": " MB_P3V3_STBY",
- "ScaleFactor": 0.1124,
+ "ScaleFactor": 0.4107,
"Thresholds": [
{
"Direction": "greater than",
@@ -123,7 +121,7 @@
{
"Index": 6,
"Name": " MB_P5V_STBY",
- "ScaleFactor": 0.1124,
+ "ScaleFactor": 0.2717,
"Thresholds": [
{
"Direction": "greater than",
@@ -143,6 +141,7 @@
{
"Index": 7,
"Name": "MB_P3V_BAT",
+ "ScaleFactor": 0.3333,
"Thresholds": [
{
"Direction": "greater than",