configurations: sbp1: Update PHY LDOs
According to the KSZ9131RNX's datasheet the 1.2V PHY LDOs operate
on 1.25V with a non-uniform margin. Update the thresholds to prevent
a sensor warning, while the LDOs are within their normal operating
condition. Account for ADC noise and use slightly relaxed thresholds.
Tested: Confirmed on the webui that the PHY LDOs are no longer marked
as critical.
Change-Id: Icfc65e4563223248b07984e52a6b80912c9c1eff
Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
diff --git a/configurations/sbp1_baseboard.json b/configurations/sbp1_baseboard.json
index 9bfd28e..93ebd14 100644
--- a/configurations/sbp1_baseboard.json
+++ b/configurations/sbp1_baseboard.json
@@ -241,25 +241,13 @@
"Direction": "greater than",
"Name": "upper critical",
"Severity": 1,
- "Value": 1.26
- },
- {
- "Direction": "greater than",
- "Name": "upper non critical",
- "Severity": 0,
- "Value": 1.236
- },
- {
- "Direction": "less than",
- "Name": "lower non critical",
- "Severity": 0,
- "Value": 1.164
+ "Value": 1.34
},
{
"Direction": "less than",
"Name": "lower critical",
"Severity": 1,
- "Value": 1.14
+ "Value": 1.2
}
],
"Type": "ADC"
@@ -274,25 +262,13 @@
"Direction": "greater than",
"Name": "upper critical",
"Severity": 1,
- "Value": 1.26
- },
- {
- "Direction": "greater than",
- "Name": "upper non critical",
- "Severity": 0,
- "Value": 1.236
- },
- {
- "Direction": "less than",
- "Name": "lower non critical",
- "Severity": 0,
- "Value": 1.164
+ "Value": 1.34
},
{
"Direction": "less than",
"Name": "lower critical",
"Severity": 1,
- "Value": 1.14
+ "Value": 1.2
}
],
"Type": "ADC"