configurations: yosemite4: add unavailableAsFailed flag to the sensors
Add InputUnavailableAsFailed as false to all the sensors that would be
unavailable when slot DC off or AC off so fan mode wouldn't be set to
fail safe mode if the sensors were unavailable.
Change-Id: I8f0ae17c9925b39f85b70ef5f70b797cc8155e26
Signed-off-by: Ricky CX Wu <ricky.cx.wu.wiwynn@gmail.com>
diff --git a/configurations/yosemite4_medusaboard_adc_ti_hsc_adi.json b/configurations/yosemite4_medusaboard_adc_ti_hsc_adi.json
index 128c89f..ecc3cc9 100644
--- a/configurations/yosemite4_medusaboard_adc_ti_hsc_adi.json
+++ b/configurations/yosemite4_medusaboard_adc_ti_hsc_adi.json
@@ -1796,6 +1796,27 @@
"Inputs": [
"MEDUSA_48VHSC0_TEMP_C",
"MEDUSA_48VHSC1_TEMP_C",
+ "MEDUSA_TEMP0_C",
+ "MEDUSA_TEMP1_C"
+ ],
+ "Name": "Stepwise_MEDUSA_Non_Critical_Sensors",
+ "NegativeHysteresis": 0,
+ "Output": [
+ 20.0
+ ],
+ "PositiveHysteresis": 0,
+ "Reading": [
+ 20.0
+ ],
+ "Type": "Stepwise",
+ "Zones": [
+ "Zone 1"
+ ]
+ },
+ {
+ "Class": "temp",
+ "InputUnavailableAsFailed": false,
+ "Inputs": [
"MEDUSA_MB1_12VHSC_TEMP_C",
"MEDUSA_MB2_12VHSC_TEMP_C",
"MEDUSA_MB3_12VHSC_TEMP_C",
@@ -1803,11 +1824,9 @@
"MEDUSA_MB5_12VHSC_TEMP_C",
"MEDUSA_MB6_12VHSC_TEMP_C",
"MEDUSA_MB7_12VHSC_TEMP_C",
- "MEDUSA_MB8_12VHSC_TEMP_C",
- "MEDUSA_TEMP0_C",
- "MEDUSA_TEMP1_C"
+ "MEDUSA_MB8_12VHSC_TEMP_C"
],
- "Name": "Stepwise_MEDUSA_Non_Critical_Sensors",
+ "Name": "Stepwise_MEDUSA_MB_12VHSC",
"NegativeHysteresis": 0,
"Output": [
20.0