Add a new query option for the effective rank order
This rank order will be changed during PSU Redundancy running,
Settings service only stores the user initial settings,
add a new option to return the current effective settings
from Redundancy service.
Tested:
With two PSUs, AC cycle the board,
// Two PSUs available
ipmitool raw 0x30 0x2E 0x05
05 02
// Wait for 2 minutes, query the current effective order
ipmitool raw 0x30 0x2E 0x06
06 01 02
ipmitool raw 0x30 0x2E 0x03
03 00 00
// Set a new order 2,1
ipmitool raw 0x30 0x2d 0x03 0x01 0x02 0x01
00
// Query the new order settings for several times, always 2,1
ipmitool raw 0x30 0x2E 0x03
03 01 02 01
// Query the current effective order for several times, it changes
ipmitool raw 0x30 0x2E 0x06
06 01 02
ipmitool raw 0x30 0x2E 0x06
06 02 01
Change-Id: I355193ea0da18abaf0dfbb3210083614018d05a8
Signed-off-by: Yong Li <yong.b.li@linux.intel.com>
1 file changed