clang-format: copy latest and re-format

clang-format-16 has some backwards incompatible changes that require
additional settings for best compatibility and re-running the formatter.
Copy the latest .clang-format from the docs repository[1] and reformat
the repository.

[1] https://gerrit.openbmc.org/c/openbmc/docs/+/63441

Further, shift the fixup for C's `_Static_assert` into src/msgbuf.h to
prevent a clang-tidy-16 error:

```
/data0/jenkins/workspace/ci-repository/openbmc/libpldm/src/msgbuf.h:315:2: error: '_Static_assert' is a C11 extension [clang-diagnostic-c11-extensions,-warnings-as-errors]
        _Static_assert(sizeof(*dst) == sizeof(ldst),
        ^
```

And fix up the function prototype in the definition of `pldm_open()`:

```
../src/requester/pldm.c:128:16: error: a function declaration without a prototype is deprecated in all versions of C [clang-diagnostic-strict-prototypes,-warnings-as-errors]
void pldm_close()
               ^
                void
```

Change-Id: I57b53f51914e39237e733d024e62ab41b3d306c1
Signed-off-by: Andrew Jeffery <andrew@aj.id.au>
diff --git a/tests/libpldm_platform_test.cpp b/tests/libpldm_platform_test.cpp
index 99b6729..0b3370d 100644
--- a/tests/libpldm_platform_test.cpp
+++ b/tests/libpldm_platform_test.cpp
@@ -3106,21 +3106,21 @@
         0x1,
         0x0,
         0x0,
-        0x0,                     // record handle
-        0x1,                     // PDRHeaderVersion
-        PLDM_NUMERIC_SENSOR_PDR, // PDRType
+        0x0,                         // record handle
+        0x1,                         // PDRHeaderVersion
+        PLDM_NUMERIC_SENSOR_PDR,     // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                         // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_MIN_LENGTH,
-        0, // dataLength
+        0,                           // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                           // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                         // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                           // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                           // entityInstanceNumber
         1,
         0,                           // containerID=1
         PLDM_NO_INIT,                // sensorInit
@@ -3145,12 +3145,12 @@
         0x80,
         0x3f, // offset=1.0
         0,
-        0, // accuracy
-        0, // plusTolerance
-        0, // minusTolerance
-        3, // hysteresis = 3
-        0, // supportedThresholds
-        0, // thresholdAndHysteresisVolatility
+        0,    // accuracy
+        0,    // plusTolerance
+        0,    // minusTolerance
+        3,    // hysteresis = 3
+        0,    // supportedThresholds
+        0,    // thresholdAndHysteresisVolatility
         0,
         0,
         0x80,
@@ -3235,19 +3235,19 @@
         0x1,                     // PDRHeaderVersion
         PLDM_NUMERIC_SENSOR_PDR, // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                     // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_SENSOR_DATA_SIZE_MIN_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_RANGE_FIELD_MIN_LENGTH,
-        0, // dataLength
+        0,                             // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                             // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                           // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                             // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                             // entityInstanceNumber
         0x1,
         0x0,                           // containerID=1
         PLDM_NO_INIT,                  // sensorInit
@@ -3331,19 +3331,19 @@
         0x1,                     // PDRHeaderVersion
         PLDM_NUMERIC_SENSOR_PDR, // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                     // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_SENSOR_DATA_SIZE_MIN_LENGTH * 2 +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_RANGE_FIELD_MIN_LENGTH * 2,
-        0, // dataLength
+        0,                            // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                            // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                          // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                            // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                            // entityInstanceNumber
         0x1,
         0x0,                          // containerID=1
         PLDM_NO_INIT,                 // sensorInit
@@ -3382,31 +3382,31 @@
         0,
         0,
         0x80,
-        0x3f, // updateInverval=1.0
+        0x3f,                           // updateInverval=1.0
         0,
-        0x10, // maxReadable = 4096
+        0x10,                           // maxReadable = 4096
         0,
         0,                              // minReadable = 0
         PLDM_RANGE_FIELD_FORMAT_UINT16, // rangeFieldFormat
         0,                              // rangeFieldsupport
         0x88,
-        0x13, // nominalValue = 5,000
+        0x13,                           // nominalValue = 5,000
         0x70,
-        0x17, // normalMax = 6,000
+        0x17,                           // normalMax = 6,000
         0xa0,
-        0x0f, // normalMin = 4,000
+        0x0f,                           // normalMin = 4,000
         0x58,
-        0x1b, // warningHigh = 7,000
+        0x1b,                           // warningHigh = 7,000
         0xb8,
-        0x0b, // warningLow = 3,000
+        0x0b,                           // warningLow = 3,000
         0x40,
-        0x1f, // criticalHigh = 8,000
+        0x1f,                           // criticalHigh = 8,000
         0xd0,
-        0x07, // criticalLow = 2,000
+        0x07,                           // criticalLow = 2,000
         0x28,
-        0x23, // fatalHigh = 9,000
+        0x23,                           // fatalHigh = 9,000
         0xe8,
-        0x03 // fatalLow = 1,000
+        0x03                            // fatalLow = 1,000
     };
 
     struct pldm_numeric_sensor_value_pdr decodedPdr;
@@ -3439,19 +3439,19 @@
         0x1,                     // PDRHeaderVersion
         PLDM_NUMERIC_SENSOR_PDR, // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                     // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_SENSOR_DATA_SIZE_MIN_LENGTH * 2 +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_RANGE_FIELD_MIN_LENGTH * 2,
-        0, // dataLength
+        0,                            // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                            // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                          // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                            // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                            // entityInstanceNumber
         0x1,
         0x0,                          // containerID=1
         PLDM_NO_INIT,                 // sensorInit
@@ -3490,31 +3490,31 @@
         0,
         0,
         0x80,
-        0x3f, // updateInverval=1.0
+        0x3f,                           // updateInverval=1.0
         0xe8,
-        0x03, // maxReadable = 1000
+        0x03,                           // maxReadable = 1000
         0x18,
         0xfc,                           // minReadable = -1000
         PLDM_RANGE_FIELD_FORMAT_SINT16, // rangeFieldFormat
         0,                              // rangeFieldsupport
         0,
-        0, // nominalValue = 0
+        0,                              // nominalValue = 0
         0xf4,
-        0x01, // normalMax = 500
+        0x01,                           // normalMax = 500
         0x0c,
-        0xfe, // normalMin = -500
+        0xfe,                           // normalMin = -500
         0xe8,
-        0x03, // warningHigh = 1,000
+        0x03,                           // warningHigh = 1,000
         0x18,
-        0xfc, // warningLow = -1,000
+        0xfc,                           // warningLow = -1,000
         0xd0,
-        0x07, // criticalHigh = 2,000
+        0x07,                           // criticalHigh = 2,000
         0x30,
-        0xf8, // criticalLow = -2,000
+        0xf8,                           // criticalLow = -2,000
         0xb8,
-        0x0b, // fatalHigh = 3,000
+        0x0b,                           // fatalHigh = 3,000
         0x48,
-        0xf4 // fatalLow = -3,000
+        0xf4                            // fatalLow = -3,000
     };
 
     struct pldm_numeric_sensor_value_pdr decodedPdr;
@@ -3547,19 +3547,19 @@
         0x1,                     // PDRHeaderVersion
         PLDM_NUMERIC_SENSOR_PDR, // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                     // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_SENSOR_DATA_SIZE_MIN_LENGTH * 4 +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_RANGE_FIELD_MIN_LENGTH * 4,
-        0, // dataLength
+        0,                            // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                            // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                          // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                            // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                            // entityInstanceNumber
         0x1,
         0x0,                          // containerID=1
         PLDM_NO_INIT,                 // sensorInit
@@ -3679,19 +3679,19 @@
         0x1,                     // PDRHeaderVersion
         PLDM_NUMERIC_SENSOR_PDR, // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                     // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_SENSOR_DATA_SIZE_MIN_LENGTH * 4 +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_RANGE_FIELD_MIN_LENGTH * 4,
-        0, // dataLength
+        0,                            // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                            // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                          // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                            // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                            // entityInstanceNumber
         0x1,
         0x0,                          // containerID=1
         PLDM_NO_INIT,                 // sensorInit
@@ -3811,19 +3811,19 @@
         0x1,                     // PDRHeaderVersion
         PLDM_NUMERIC_SENSOR_PDR, // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                     // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_SENSOR_DATA_SIZE_MIN_LENGTH * 4 +
             PLDM_PDR_NUMERIC_SENSOR_PDR_VARIED_RANGE_FIELD_MIN_LENGTH * 4,
-        0, // dataLength
+        0,                            // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                            // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                          // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                            // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                            // entityInstanceNumber
         0x1,
         0x0,                          // containerID=1
         PLDM_NO_INIT,                 // sensorInit
@@ -3940,21 +3940,21 @@
         0x1,
         0x0,
         0x0,
-        0x0,                     // record handle
-        0x1,                     // PDRHeaderVersion
-        PLDM_NUMERIC_SENSOR_PDR, // PDRType
+        0x0,                         // record handle
+        0x1,                         // PDRHeaderVersion
+        PLDM_NUMERIC_SENSOR_PDR,     // PDRType
         0x0,
-        0x0, // recordChangeNumber
+        0x0,                         // recordChangeNumber
         PLDM_PDR_NUMERIC_SENSOR_PDR_FIXED_LENGTH,
-        0, // dataLength
+        0,                           // dataLength
         0,
-        0, // PLDMTerminusHandle
+        0,                           // PLDMTerminusHandle
         0x1,
-        0x0, // sensorID=1
+        0x0,                         // sensorID=1
         PLDM_ENTITY_POWER_SUPPLY,
-        0, // entityType=Power Supply(120)
+        0,                           // entityType=Power Supply(120)
         1,
-        0, // entityInstanceNumber
+        0,                           // entityInstanceNumber
         0x1,
         0x0,                         // containerID=1
         PLDM_NO_INIT,                // sensorInit