swift: Add fan control for bring-up

To support the swift system bring-up, install the cooling type and fan
control application with minimal configuration to run fans at full
speed(9500 RPMs).

Tested:
    Cooling type included in image and configured correctly
    Fan control included in image and configured correctly

Change-Id: Ide1ade5bcf892daa416c5b6253e7b6aa33042f2e
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
diff --git a/meta-witherspoon/recipes-phosphor/fans/swift-phosphor-fan-control-zone-config-native/zones.yaml b/meta-witherspoon/recipes-phosphor/fans/swift-phosphor-fan-control-zone-config-native/zones.yaml
new file mode 100644
index 0000000..c10c6c1
--- /dev/null
+++ b/meta-witherspoon/recipes-phosphor/fans/swift-phosphor-fan-control-zone-config-native/zones.yaml
@@ -0,0 +1,68 @@
+manager_configuration:
+  power_on_delay: 20
+
+zone_configuration:
+
+#Air cooled zones
+- zone_conditions:
+  - name: air_cooled_chassis
+
+  zones:
+    - zone: 0
+      cooling_profiles:
+      - air
+      - all
+      full_speed: 9500
+      default_floor: 8000
+      increase_delay: 5
+      decrease_interval: 30
+      interfaces:
+          - name: xyz.openbmc_project.Control.ThermalMode
+            properties:
+                - name: Supported
+                  type: array[string]
+                  values:
+                      - value: DEFAULT
+                        description: >
+                            Default thermal control mode
+                - name: Current
+                  type: string
+                  persist: true
+                  values:
+                      - value: DEFAULT
+                        description: >
+                            Set current thermal control mode to the
+                            default which will be replaced on startup if
+                            another supported mode was selected & persisted.
+
+#Water cooled zones
+- zone_conditions:
+  - name: water_and_air_cooled_chassis
+
+  zones:
+    - zone: 0
+      cooling_profiles:
+      - water
+      - all
+      full_speed: 9500
+      default_floor: 8000
+      increase_delay: 5
+      decrease_interval: 30
+      interfaces:
+          - name: xyz.openbmc_project.Control.ThermalMode
+            properties:
+                - name: Supported
+                  type: array[string]
+                  values:
+                      - value: DEFAULT
+                        description: >
+                            Default thermal control mode
+                - name: Current
+                  type: string
+                  persist: true
+                  values:
+                      - value: DEFAULT
+                        description: >
+                            Set current thermal control mode to the
+                            default which will be replaced on startup if
+                            another supported mode was selected & persisted.