swift: Add dbus monitor policy configurations
Swift has two power supplies, same as Witherspoon, therefore will use
the same power supply policy configuration.
Swift and Witherspoon will also share the event policy configuration for
OCC throttling.
The thermal policy configuration will be shared between Swift and
Witherspoon, but may change for air cooled Swift to not also shutdown at
3 or more cores over 115C.
The fan policy configurations will be different for Swift, therefore
they will be separate. At this time, there are some areas unknown on how
fan presence and functional states will be handled for both air and
water cooled Swift machines, so these are configured to be the same.
Tested:
Built witherspoon phosphor-dbus-monitor resulting in no image change
Built swift phosphor-dbus-monitor resulting in correct policies
Change-Id: I0b7a55c791fd78af5732a33b8d44bfddc2d0b20f
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
7 files changed