Add mihawk sensor, fan control and d-bus monitor

Most of mihawk's sensors are different from witherspoon, so I temporarily
added the mihawk part and did not change the witherspoon.

Add mihawk version of fan control and d-bus monitor.
Mihawk does not have a water cooled mode, so another independent folder is added.

Tested: 1.Shut down the system if more than three cores
          have a temperature greater than 100 degrees Celcius.
        2.Fan control support cpu core, dimm, Onboard.
        3.Confirm that sensor is able to return normally via REST.

Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
Change-Id: I346fd70fe435eef4a745dc5863ce023037e0f151
diff --git a/meta-witherspoon/recipes-phosphor/fans/phosphor-fan/mihawk/phosphor-cooling-type@.service b/meta-witherspoon/recipes-phosphor/fans/phosphor-fan/mihawk/phosphor-cooling-type@.service
new file mode 100644
index 0000000..9232b13
--- /dev/null
+++ b/meta-witherspoon/recipes-phosphor/fans/phosphor-fan/mihawk/phosphor-cooling-type@.service
@@ -0,0 +1,15 @@
+[Unit]
+Description=Phosphor Cooling Type
+Wants=mapper-wait@-xyz-openbmc_project-inventory.service
+After=mapper-wait@-xyz-openbmc_project-inventory.service
+ConditionPathExists={envfiledir}/obmc/phosphor-fan/phosphor-cooling-type-%i.conf
+
+[Service]
+Type=oneshot
+RemainAfterExit=yes
+EnvironmentFile={envfiledir}/obmc/phosphor-fan/phosphor-cooling-type-%i.conf
+ExecStart=/usr/bin/env phosphor-cooling-type ${{OBJPATH}} ${{AIR}}
+SyslogIdentifier=phosphor-cooling-type
+
+[Install]
+RequiredBy=multi-user.target