commit | 454e8520de57b6ab8f1ca8a96afd972bcadd42a1 | [log] [tgz] |
---|---|---|
author | Lei YU <mine260309@gmail.com> | Fri Jul 20 16:33:56 2018 +0800 |
committer | Brad Bishop <bradleyb@fuzziesquirrel.com> | Mon Jul 23 12:40:28 2018 +0000 |
tree | 933163a0678a9ef69bc28a707594736df985e890 | |
parent | c9a386bfceff525497147f05a8d6c9fc25105cee [diff] |
meta-romulus: Add led groups for faults Add fault groups, e.g. core, dimm fault groups in led config, so that fault monitor could set related fault group to turn on the fault led. Tested: Verify the led fault groups are created, and when asserted, the fault led is turned on. Change-Id: Iace27d605c11b8c5b3d33685eecdaffb402fc6ad Signed-off-by: Lei YU <mine260309@gmail.com>