Ensure host-shutdown target calls the host-stop target

As a part of the soft power off (host-shutdown) ensure
that the host-stop target always gets called.  Updated the
involved services to ensure they are run in the correct order.

Change-Id: I7e9113631786f0d0cb0f89b94c4b97fdc0328e7b
Signed-off-by: Andrew Geissler <andrewg@us.ibm.com>
diff --git a/common/recipes-phosphor/chassis/obmc-op-control-power/op-power-stop@.service b/common/recipes-phosphor/chassis/obmc-op-control-power/op-power-stop@.service
index dd3570e..0833afb 100644
--- a/common/recipes-phosphor/chassis/obmc-op-control-power/op-power-stop@.service
+++ b/common/recipes-phosphor/chassis/obmc-op-control-power/op-power-stop@.service
@@ -2,6 +2,7 @@
 Description=Stop Power%i
 Wants=obmc-power-stop@%i.target
 Before=obmc-power-stop@%i.target
+Wants=obmc-power-stop-pre@%i.target
 After=obmc-power-stop-pre@%i.target
 Wants=mapper-wait@-org-openbmc-control-power%i.service
 After=mapper-wait@-org-openbmc-control-power%i.service