commit | b965c2201a52ed66efe06ee4ec6c2c51a16b453e | [log] [tgz] |
---|---|---|
author | Patrick Williams <patrick@stwcx.xyz> | Fri Aug 16 15:21:28 2024 -0400 |
committer | Patrick Williams <patrick@stwcx.xyz> | Fri Aug 16 15:21:28 2024 -0400 |
tree | 5e26a573b354dfd63ce0b6ddc7277dcb4cbaa9e4 | |
parent | 85055f997acddcf9d7ca49ed0981cb7700587b98 [diff] |
clang-format: re-format for clang-18 clang-format-18 isn't compatible with the clang-format-17 output, so we need to reformat the code with the latest version. The way clang-18 handles lambda formatting also changed, so we have made changes to the organization default style format to better handle lambda formatting. See I5e08687e696dd240402a2780158664b7113def0e for updated style. See Iea0776aaa7edd483fa395e23de25ebf5a6288f71 for clang-18 enablement. Change-Id: I2f8eeee40b0b2583092d351979dd77fd277a97ba Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
To build this project, run the following shell commands:
meson setup build meson compile -C build
To test:
dbus-run-session meson test -C build
Running the server requires a serial port (e.g. /dev/ttyS0):
touch obmc-console.conf ./obmc-console-server --config obmc-console.conf ttyS0
To connect to the server, simply run the client:
./obmc-console-client
To disconnect the client, use the standard ~.
combination.
This shows how the host UART connection is abstracted within the BMC as a Unix domain socket.
+---------------------------------------------------------------------------------------------+ | | | obmc-console-client unix domain socket obmc-console-server | | | | +----------------------+ +------------------------+ | | | client.2200.conf | +---------------------+ | server.ttyVUART0.conf | | +---+--+ +----------------------+ | | +------------------------+ +--------+-------+ Network | 2200 +--> +->+ @obmc-console.host0 +<-+ <--+ /dev/ttyVUART0 | UARTs +---+--+ | console-id = "host0" | | | | console-id = "host0" | +--------+-------+ | | | +---------------------+ | | | | +----------------------+ +------------------------+ | | | | | | | +---------------------------------------------------------------------------------------------+
This supports multiple independent consoles. The console-id
is a unique portion for the unix domain socket created by the obmc-console-server instance. The server needs to know this because it needs to know what to name the pipe; the client needs to know it as it needs to form the abstract socket name to which to connect.
In some hardware designs, multiple UARTS may be available behind a Mux. Please reference docs/mux-support.md in that case.
For developing obmc-console, we can use pseudo terminals (pty's) in Linux.
The socat command will output names of 2 pty's, one of which is the master and the other one is the slave. The master pty can be used to emulate a UART.
$ socat -d -d pty,raw,echo=0,link=pty1 pty,raw,echo=0,link=pty2 $ obmc-console-server --console-id dev $(realpath pty2) $ obmc-console-client -i dev # this message should appear for the client $ echo "hi" > pty1