obmc-console: Provide a default value for `console-id`. 4e7186918599 ("Fixed broken dbus interface for multiple consoles") introduced the requirement that `console-id` be specified in the configuration files for both the client and server. It was paired with a fix to platform configurations in the OpenBMC bitbake metadata[1]. In theory this should have worked, but because specifying `console-id` wasn't a requirement, not all platforms supplied a client configuration. Instead they relied on the default behaviour. [1]: https://gerrit.openbmc.org/c/openbmc/openbmc/+/62712 Remove the requirement that a `console-id` be specified and instead provide a default value that can be overridden by configuration. This carries forward the consequence from 4e7186918599 ("Fixed broken dbus interface for multiple consoles") that the original `\0obmc-console` abstract socket will never be created. This doesn't resolve the break in ipmid or bmcweb, but resolves the break to SSH-based SOL on platforms not supplying client configuration files for one of their consoles. The fix to bmcweb (whose strategy can also be applied to ipmid) is currently being prototyped[2]. [2]: https://discord.com/channels/775381525260664832/1083551792094249051/1103867159412752424 A deeper treatment of the problems, impacts, and solutions is provided in [3]. [3]: https://amboar.github.io/notes/2023/05/08/happenings-in-obmc-console.html Fixes: 4e7186918599 ("Fixed broken dbus interface for multiple consoles") Signed-off-by: Andrew Jeffery <andrew@aj.id.au> Change-Id: I970578f1b695f729f6524c4da6bba6e89bf14d52
To build this project, run the following shell commands:
meson setup build meson compile -C build
To test:
meson test -C build
Running the server requires a serial port (e.g. /dev/ttyS0):
touch obmc-console.conf ./obmc-console-server --config obmc-console.conf ttyS0
To connect to the server, simply run the client:
./obmc-console-client
To disconnect the client, use the standard ~.
combination.
This shows how the host UART connection is abstracted within the BMC as a Unix domain socket.
+---------------------------------------------------------------------------------------------+ | | | obmc-console-client unix domain socket obmc-console-server | | | | +----------------------+ +------------------------+ | | | client.2200.conf | +---------------------+ | server.ttyVUART0.conf | | +---+--+ +----------------------+ | | +------------------------+ +--------+-------+ Network | 2200 +--> +->+ @obmc-console.host0 +<-+ <--+ /dev/ttyVUART0 | UARTs +---+--+ | console-id = "host0" | | | | console-id = "host0" | +--------+-------+ | | | +---------------------+ | | | | +----------------------+ +------------------------+ | | | | | | | +---------------------------------------------------------------------------------------------+
This supports multiple independent consoles. The console-id
is a unique portion for the unix domain socket created by the obmc-console-server instance. The server needs to know this because it needs to know what to name the pipe; the client needs to know it as it needs to form the abstract socket name to which to connect.