BMC planar serial number verification
Resolves openbmc/openbmc-test-automation#972
Change-Id: Ieb88d8b48d8fcf9a0b40d5df10bce146780fc7e3
Signed-off-by: George Keishing <gkeishin@in.ibm.com>
diff --git a/tests/test_inventory.robot b/tests/test_inventory.robot
index 76b03b7..e3b3878 100644
--- a/tests/test_inventory.robot
+++ b/tests/test_inventory.robot
@@ -48,6 +48,9 @@
# },
${json_data}= Get Inventory system/chassis/motherboard/boxelder/bmc
Should Be True ${json_data["data"]["Present"]}
+ Should Not Be Equal As Strings
+ ... ${json_data["data"]["SerialNumber"]} 000000000000
+ ... msg=BMC planar serial number invalid.
Verify Boxelder MAC Address Property Is Populated