Added test for Server LED OFF
Changes:
- Test is verifying GUI server LED OFF state with Redfish value
Change-Id: I5fa67a9158125a7a62c1d57503ef308ff88c7f83
Signed-off-by: Sushma M M <sushmm99@in.ibm.com>
diff --git a/gui/gui_test/control_menu/test_server_led_sub_menu.robot b/gui/gui_test/control_menu/test_server_led_sub_menu.robot
index 9271c84..3e71b19 100644
--- a/gui/gui_test/control_menu/test_server_led_sub_menu.robot
+++ b/gui/gui_test/control_menu/test_server_led_sub_menu.robot
@@ -59,6 +59,21 @@
Verify Server LED using Redfish and GUI On
+Verify Server LED OFF
+ [Documentation] Turn OFF the server LED button using GUI and verify it via Redfish.
+ [Tags] Verify_Server_LED_OFF
+
+ # Turn ON the server LED via Redfish.
+ Redfish.Patch /redfish/v1/Systems/system body={"IndicatorLED":"Lit"} valid_status_codes=[200, 204]
+
+ # Turn Off the server LED via GUI.
+ Click Element At Coordinates ${xpath_led_toggle} 0 0
+ Wait Until Element Contains ${xpath_led_value} Off timeout=15
+
+ # Verify server LED via Redfish and GUI.
+ Verify Server LED using Redfish and GUI Off
+
+
*** Keywords ***
Test Setup Execution