Modified vmi network config testcases
Changes:
-Add Multiple IP Addreses On VMI Interface And Verify
-Modify IP Addresses On VMI Interface And Verify
-Verify Successful VMI IP Static Configuration On HOST Boot After Session Delete
-Verify VMI Static IP Configuration Persist On BMC Reset Before Host Boot
Change-Id: Ie28494ed5d603b9324f28e27252ca23707063a1b
Signed-off-by: shrsuman123 <shrsuman@in.ibm.com>
diff --git a/openpower/ext_interfaces/test_vmi.robot b/openpower/ext_interfaces/test_vmi.robot
index d64fa6a..4b5f3e0 100644
--- a/openpower/ext_interfaces/test_vmi.robot
+++ b/openpower/ext_interfaces/test_vmi.robot
@@ -82,7 +82,7 @@
Add Multiple IP Addreses On VMI Interface And Verify
[Documentation] Add multiple IP addreses on VMI interface and verify.
[Tags] Add_Multiple_IP_Addreses_On_VMI_Interface_And_Verify
- [Teardown] Run Keywords Delete VMI IPv4 Address IPv4Addresses AND Test Teardown
+ [Teardown] Run Keywords Delete VMI IPv4 Address IPv4Addresses AND FFDC On Test Case Fail
${ip1}= Create dictionary Address=10.5.5.10 SubnetMask=255.255.252.0 Gateway=0.0.0.0
${ip2}= Create dictionary Address=10.5.5.11 SubnetMask=255.255.252.0 Gateway=0.0.0.0
@@ -98,7 +98,7 @@
[Documentation] Modify IP addresses on VMI interface and verify.
[Tags] Modify_IP_Addresses_On_VMI_Interface_And_Verify
[Template] Verify Assigning Static IPv4 Address To VMI
- [Teardown] Run keywords Delete VMI IPv4 Address IPv4Addresses AND Test Teardown
+ [Teardown] Run keywords Delete VMI IPv4 Address IPv4Addresses AND FFDC On Test Case Fail
# ip gateway netmask del_curr_ip host_reboot valid_status_code
10.5.5.10 0.0.0.0 255.255.252.0 ${False} ${True} ${HTTP_ACCEPTED}
@@ -143,7 +143,7 @@
Verify Successful VMI IP Static Configuration On HOST Boot After Session Delete
[Documentation] Verify VMI IP static Configuration On HOST Boot After session deleted.
[Tags] Verify_Successful_VMI_IP_Static_Configuration_On_HOST_Boot_After_Session_Delete
- [Teardown] Run keywords Delete VMI IPv4 Address IPv4Addresses AND Test Teardown
+ [Teardown] Run keywords Delete VMI IPv4 Address IPv4Addresses AND FFDC On Test Case Fail
Set Static IPv4 Address To VMI ${test_ipv4} ${test_gateway} ${test_netmask}
@@ -151,7 +151,7 @@
Redfish.Delete ${session_info["location"]}
# Create a new Redfish session
- Run Keywords Redfish Power Off AND Redfish Power On AND Redfish.Login
+ Run Keywords Redfish.Login AND Redfish Power Off AND Redfish Power On
Verify VMI Network Interface Details ${test_ipv4} Static ${test_gateway} ${test_netmask}
@@ -171,10 +171,10 @@
Verify VMI Static IP Configuration Persist On BMC Reset Before Host Boot
[Documentation] Verify VMI static IP configuration persist on BMC reset.
[Tags] Verify_VMI_Static_IP_Configuration_Persist_On_BMC_Reset_Before_Host_Boot
- [Teardown] Run keywords Delete VMI IPv4 Address IPv4Addresses AND Test Teardown
+ [Teardown] Run keywords Delete VMI IPv4 Address IPv4Addresses AND FFDC On Test Case Fail
Set Static IPv4 Address To VMI ${test_ipv4} ${test_gateway} ${test_netmask}
- Run keywords Redfish OBMC Reboot (off) AND Redfish Power On
+ Run keywords OBMC Reboot (off) AND Redfish Power On
# Verifying the VMI static configuration
Verify VMI Network Interface Details ${test_ipv4} Static ${test_gateway} ${test_netmask}