Check power supplies watts and voltages readings
Signed-off-by: Marissa Garza <garzam@us.ibm.com>
Change-Id: I4d42c2facc12247d2138162793004b4b2c97373e
diff --git a/data/variables.py b/data/variables.py
index 245c3dd..22bba32 100755
--- a/data/variables.py
+++ b/data/variables.py
@@ -163,6 +163,10 @@
REDFISH_CHASSIS_THERMAL_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_THERMAL
REDFISH_CHASSIS_POWER = 'chassis/Power/'
REDFISH_CHASSIS_POWER_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_POWER
+REDFISH_CHASSIS_PSUPPLY0 = 'powersupply0/Power/'
+REDFISH_CHASSIS_PSUPPLY1 = 'powersupply1/Power/'
+REDFISH_CHASSIS_PSUPPLY0_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_PSUPPLY0
+REDFISH_CHASSIS_PSUPPLY1_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_PSUPPLY1
# Boot options and URI variables.
POWER_ON = 'On'
diff --git a/redfish/systems/test_powersupply_readings.robot b/redfish/systems/test_powersupply_readings.robot
new file mode 100755
index 0000000..835a288
--- /dev/null
+++ b/redfish/systems/test_powersupply_readings.robot
@@ -0,0 +1,116 @@
+*** Settings ***
+Documentation Get the systems' power supply voltage readings.
+
+Resource ../../lib/bmc_redfish_resource.robot
+Resource ../../lib/bmc_redfish_utils.robot
+Resource ../../lib/openbmc_ffdc.robot
+Library ../../lib/gen_robot_valid.py
+
+Suite Setup Suite Setup Execution
+Suite Teardown Suite Teardown Execution
+Test Setup Printn
+Test Teardown Test Teardown Execution
+
+
+*** Test Cases ***
+
+Verify Power Supplies Input Watts
+ [Documentation] Verify there are no invalid power supply input watt records.
+ [Tags] Verify_Power_Supplies_Input_Watts
+ [Template] Verify Watts Record
+
+ # record_type redfish_uri reading_type
+ PowerSupplies ${REDFISH_CHASSIS_PSUPPLY0_URI} PowerInputWatts
+ PowerSupplies ${REDFISH_CHASSIS_PSUPPLY1_URI} PowerInputWatts
+
+
+Verify Power Supplies Input Output Voltages
+ [Documentation] Verify there are no invalid power supply voltage records.
+ [Tags] Verify_Power_Supplies_Input_Output_Voltages
+ [Template] Verify Voltage Records
+
+ # record_type redfish_uri reading_type
+ Voltages ${REDFISH_CHASSIS_PSUPPLY0_URI} ReadingVolts
+ Voltages ${REDFISH_CHASSIS_PSUPPLY1_URI} ReadingVolts
+
+
+*** Keywords ***
+
+Verify Watts Record
+ [Documentation] Verify the power watt records.
+ [Arguments] ${record_type} ${redfish_uri} ${reading_type}
+
+ # Description of Arguments(s):
+ # record_type The sensor record type (e.g. "PowerSupplies")
+ # redfish_uri The power supply URI (e.g. /redfish/v1/Chassis/powersupply0/Power)
+ # reading_type The power watt readings (e.g. "PowerInputWatts")
+
+ Verify Valid Records ${record_type} ${redfish_uri} ${reading_type}
+
+
+Verify Voltage Records
+ [Documentation] Verify the power voltage records.
+ [Arguments] ${record_type} ${redfish_uri} ${reading_type}
+
+ # Description of Arguments(s):
+ # record_type The sensor record type (e.g. "Voltages")
+ # redfish_uri The power supply URI (e.g. /redfish/v1/Chassis/powersupply0/Power)
+ # reading_type The power voltage readings (e.g. "ReadingVolts")
+
+ Verify Valid Records ${record_type} ${redfish_uri} ${reading_type}
+
+ ${records}= Redfish.Get Attribute
+ ... ${redfish_uri} ${record_type}
+
+ ${invalid_records}= Evaluate
+ ... [x for x in ${records} if not x['LowerThresholdNonCritical'] <= x['${reading_type}'] <= x['UpperThresholdNonCritical']]
+
+ ${num_invalid_records}= Get Length ${invalid_records}
+ Run Keyword If ${num_invalid_records} > ${0}
+ ... Rprint Vars num_invalid_records invalid_records
+ Rvalid Value num_invalid_records valid_values=[0]
+
+
+Verify Valid Records
+ [Documentation] Verify all the valid records.
+ [Arguments] ${record_type} ${redfish_uri} ${reading_type}
+
+ # Description of Arguments(s):
+ # record_type The sensor record type (e.g. "PowerSupplies")
+ # redfish_uri The power supply URI (e.g. /redfish/v1/Chassis/powersupply0/Power)
+ # reading_type The power watt readings (e.g. "PowerInputWatts")
+
+ # A valid record will have "State" key "Enabled" and "Health" key "OK".
+ ${records}= Redfish.Get Attribute
+ ... ${redfish_uri} ${record_type}
+
+ ${num_records}= Get Length ${records}
+ Rprint Vars num_records records
+
+ ${invalid_records}= Filter Struct ${records}
+ ... [('Health', '^OK$'), ('State', '^Enabled$'), ('${reading_type}', '')] regex=1 invert=1
+ ${num_invalid_records}= Get Length ${invalid_records}
+
+ Run Keyword If ${num_invalid_records} > ${0}
+ ... Rprint Vars num_invalid_records invalid_records
+ Rvalid Value num_invalid_records valid_values=[0]
+
+
+Suite Teardown Execution
+ [Documentation] Do the post suite teardown.
+
+ Redfish.Logout
+
+
+Suite Setup Execution
+ [Documentation] Do test case setup tasks.
+
+ Printn
+ Redfish Power On
+ Redfish.Login
+
+
+Test Teardown Execution
+ [Documentation] Do the post test teardown.
+
+ FFDC On Test Case Fail