Verify PEL log after host power on
Change-Id: I5ca50c1defb9a9144fd3148de7f1e5c39fe6893a
Signed-off-by: Rahul Maheshwari <rahulmaheshwari@in.ibm.com>
diff --git a/openpower/pel/test_bmc_pel.robot b/openpower/pel/test_bmc_pel.robot
index a77f96e..3a01054 100644
--- a/openpower/pel/test_bmc_pel.robot
+++ b/openpower/pel/test_bmc_pel.robot
@@ -3,6 +3,7 @@
Library ../../lib/pel_utils.py
Variables ../../data/pel_variables.py
+Resource ../../lib/list_utils.robot
Resource ../../lib/openbmc_ffdc.robot
Test Setup Redfish.Login
@@ -152,6 +153,23 @@
Valid Value bmc_version ['${bmc_version}']
+Verify PEL Log After Host Poweron
+ [Documentation] Verify PEL log generation while booting host.
+ [Tags] Verify_PEL_Log_After_Host_Poweron
+
+ Redfish Power Off stack_mode=skip
+ Redfish Purge Event Log
+ Redfish Power On stack_mode=skip
+
+ ${pel_informational_error}= Get PEL Log IDs User Header Event Severity Informational Event
+ ${pel_bmc_created_error}= Get PEL Log IDs Private Header Creator Subsystem BMC
+
+ # Get BMC created non-infomational error.
+ ${pel_bmc_error}= Subtract Lists ${pel_bmc_created_error} ${pel_informational_error}
+
+ Should Be Empty ${pel_bmc_error} msg=Unexpected error log generated during Host poweron.
+
+
*** Keywords ***
Create Test PEL Log
@@ -174,6 +192,53 @@
BMC Execute Command ${CMD_INTERNAL_FAILURE}
+Get PEL Log IDs
+ [Documentation] Returns the list of PEL log IDs which contains given field's value.
+ [Arguments] ${pel_section} ${pel_field} @{pel_field_value}
+
+ # Description of argument(s):
+ # pel_section The section of PEL (e.g. Private Header, User Header).
+ # pel_field The PEL field (e.g. Event Severity, Event Type).
+ # pel_field_value The list of PEL's field value (e.g. Unrecoverable Error).
+
+ ${pel_ids}= Get PEL Log Via BMC CLI
+ @{pel_id_list}= Create List
+
+ FOR ${id} IN @{pel_ids}
+ ${pel_output}= Peltool -i ${id}
+ # Example of PEL output from "peltool -i <id>" command.
+ # [Private Header]:
+ # [Created at]: 08/24/1928 12:04:06
+ # [Created by]: 0x584D
+ # [Sub-section type]: 0
+ # [Entry Id]: 0x50000BB7
+ # [Platform Log Id]: 0x8200061D
+ # [CSSVER]:
+ # [Section Version]: 1
+ # [Creator Subsystem]: PHYP
+ # [BMC Event Log Id]: 341
+ # [Committed at]: 03/25/1920 12:06:22
+ # [User Header]:
+ # [Log Committed by]: 0x4552
+ # [Action Flags]:
+ # [0]: Report Externally
+ # [Subsystem]: I/O Subsystem
+ # [Event Type]: Miscellaneous, Informational Only
+ # [Sub-section type]: 0
+ # [Event Scope]: Entire Platform
+ # [Event Severity]: Informational Event
+ # [Host Transmission]: Not Sent
+ # [Section Version]: 1
+
+ ${pel_section_output}= Get From Dictionary ${pel_output} ${pel_section}
+ ${pel_field_output}= Get From Dictionary ${pel_section_output} ${pel_field}
+ Run Keyword If '${pel_field_output}' in @{pel_field_value} Append To List ${pel_id_list} ${id}
+ END
+ Sort List ${pel_id_list}
+
+ [Return] ${pel_id_list}
+
+
Get PEL Log Via BMC CLI