meta-ampere: mtjade: handle HIGHTEMP via multi-gpio-monitor
Change to handle HIGHTEMP event via multi-gpio-monitor application,
replacing ampere-gpio-handling.
Tested:
1. Stop fan monitor service
2. Stress CPU HOST
stress-ng.sh 600 5 max 100
3. Wait SOC Temp goes over 105 degree.
5. Check for HIGHTEMP event log.
Signed-off-by: Thang Q. Nguyen <thang@os.amperecomputing.com>
Change-Id: Ia6b34c7d1d7b458e6db60ca79a7a091e19ecaf06
diff --git a/meta-ampere/meta-jade/recipes-phosphor/gpio/phosphor-gpio-monitor_%.bbappend b/meta-ampere/meta-jade/recipes-phosphor/gpio/phosphor-gpio-monitor_%.bbappend
index f798fee..2a9ed5b 100644
--- a/meta-ampere/meta-jade/recipes-phosphor/gpio/phosphor-gpio-monitor_%.bbappend
+++ b/meta-ampere/meta-jade/recipes-phosphor/gpio/phosphor-gpio-monitor_%.bbappend
@@ -15,6 +15,8 @@
SYSTEMD_SERVICE:${PN}-monitor += " \
ampere-host-shutdown-ack@.service \
ampere_overtemp@.service \
+ ampere_hightemp_start@.service \
+ ampere_hightemp_stop@.service \
ampere_scp_failover.service \
psu_hotswap_reset@.service \
"