blob: 050c8b43c682fe8566c7ce9a2cc87242c41be742 [file] [log] [blame]
From c9b6d4589620275a625121b0ea9f4cc4c93b608a Mon Sep 17 00:00:00 2001
From: Ian Goegebuer <goegebuer@google.com>
Date: Tue, 10 Nov 2020 14:20:47 -0800
Subject: [PATCH] pid/zone: Add the ability to dynamically set the failSafe
percent
This change advertises the failSafe percent as a FanSpeed interface
added to the the FanCtrl object generated by the config.json file.
The target method added in this case sets the failSafePerecent
out of 255 with 255 being 100% and 0 being 0%.
Example:
`busctl set-property xyz.openbmc_project.State.FanCtrl /xyz/openbmc_project/settings/fanctrl/zone1 xyz.openbmc_project.Control.FanSpeed Target t 178`
Sets the failSafePercent to 69.8% or ~70%
`busctl set-property xyz.openbmc_project.State.FanCtrl /xyz/openbmc_project/settings/fanctrl/zone1 xyz.openbmc_project.Control.FanSpeed Target t 250`
Sets the failSafePercent to 98%
Signed-off-by: Ian Goegebuer <goegebuer@google.com>
Change-Id: Ief538d865dc1c654427ed9792496ab368e8803e2
---
pid/zone.cpp | 11 +++++++++++
pid/zone.hpp | 11 +++++++++--
pid/zone_interface.hpp | 1 +
3 files changed, 21 insertions(+), 2 deletions(-)
diff --git a/pid/zone.cpp b/pid/zone.cpp
index 441031a..24f6e84 100644
--- a/pid/zone.cpp
+++ b/pid/zone.cpp
@@ -120,6 +120,11 @@ double DbusPidZone::getFailSafePercent(void) const
return _failSafePercent;
}
+void DbusPidZone::setFailSafePercent(double newFailSafe)
+{
+ _failSafePercent = newFailSafe;
+}
+
double DbusPidZone::getMinThermalSetpoint(void) const
{
return _minThermalOutputSetPt;
@@ -459,4 +464,10 @@ bool DbusPidZone::failSafe() const
return getFailSafeMode();
}
+uint64_t DbusPidZone::target(uint64_t value)
+{
+ setFailSafePercent(((double)value / 255) * 100.0);
+ return ModeObject::target(value);
+}
+
} // namespace pid_control
diff --git a/pid/zone.hpp b/pid/zone.hpp
index 3bea9c2..c0d1d22 100644
--- a/pid/zone.hpp
+++ b/pid/zone.hpp
@@ -10,6 +10,7 @@
#include <sdbusplus/bus.hpp>
#include <sdbusplus/server.hpp>
+#include <xyz/openbmc_project/Control/FanSpeed/server.hpp>
#include <xyz/openbmc_project/Control/Mode/server.hpp>
#include <fstream>
@@ -22,7 +23,9 @@
template <typename... T>
using ServerObject = typename sdbusplus::server::object::object<T...>;
using ModeInterface = sdbusplus::xyz::openbmc_project::Control::server::Mode;
-using ModeObject = ServerObject<ModeInterface>;
+using FanSpeedInterface =
+ sdbusplus::xyz::openbmc_project::Control::server::FanSpeed;
+using ModeObject = ServerObject<ModeInterface, FanSpeedInterface>;
namespace pid_control
{
@@ -63,6 +66,7 @@ class DbusPidZone : public ZoneInterface, public ModeObject
void clearSetPoints(void) override;
void clearRPMCeilings(void) override;
double getFailSafePercent(void) const override;
+ void setFailSafePercent(double) override;
double getMinThermalSetpoint(void) const;
Sensor* getSensor(const std::string& name) override;
@@ -88,6 +92,9 @@ class DbusPidZone : public ZoneInterface, public ModeObject
/* Method for reading whether in fail-safe mode over dbus */
bool failSafe() const override;
+ /* Method for setting the failSafePercent over dbus */
+ uint64_t target(uint64_t value) override;
+
private:
std::ofstream _log;
@@ -95,7 +102,7 @@ class DbusPidZone : public ZoneInterface, public ModeObject
double _maximumSetPoint = 0;
bool _manualMode = false;
const double _minThermalOutputSetPt;
- const double _failSafePercent;
+ double _failSafePercent;
std::set<std::string> _failSafeSensors;
diff --git a/pid/zone_interface.hpp b/pid/zone_interface.hpp
index a024c0e..9ea89c1 100644
--- a/pid/zone_interface.hpp
+++ b/pid/zone_interface.hpp
@@ -70,6 +70,7 @@ class ZoneInterface
* fail safe.
*/
virtual double getFailSafePercent() const = 0;
+ virtual void setFailSafePercent(double newFailSafe) = 0;
/** Return if the zone is set to manual mode. false equates to automatic
* mode (the default).
--
2.29.2.222.g5d2a92d10f8-goog