Add mihawk sensor, fan control and d-bus monitor
Most of mihawk's sensors are different from witherspoon, so I temporarily
added the mihawk part and did not change the witherspoon.
Add mihawk version of fan control and d-bus monitor.
Mihawk does not have a water cooled mode, so another independent folder is added.
Tested: 1.Shut down the system if more than three cores
have a temperature greater than 100 degrees Celcius.
2.Fan control support cpu core, dimm, Onboard.
3.Confirm that sensor is able to return normally via REST.
(From meta-ibm rev: 949f91431bba2f0139cc823d674a741f9590c885)
Signed-off-by: Ben Pai <Ben_Pai@wistron.com>
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
Change-Id: Icc401f32c67b622f0f1448e1166112e02c135a8f
Signed-off-by: Brad Bishop <bradleyb@fuzziesquirrel.com>
diff --git a/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan_%.bbappend b/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan_%.bbappend
index 88c32ff..085857c 100644
--- a/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan_%.bbappend
+++ b/meta-ibm/meta-witherspoon/recipes-phosphor/fans/phosphor-fan_%.bbappend
@@ -3,9 +3,14 @@
# Package configuration
FAN_PACKAGES_append_ibm-ac-server = " \
phosphor-cooling-type \
-"
+ "
+
+FAN_PACKAGES_append_mihawk = " \
+ phosphor-cooling-type \
+ "
PACKAGECONFIG_append_ibm-ac-server = " cooling-type"
+PACKAGECONFIG_append_mihawk = " cooling-type"
TMPL_COOLING = "phosphor-cooling-type@.service"
INSTFMT_COOLING = "phosphor-cooling-type@{0}.service"
@@ -15,10 +20,14 @@
FILES_phosphor-cooling-type_append_ibm-ac-server = " ${bindir}/phosphor-cooling-type"
SYSTEMD_SERVICE_phosphor-cooling-type_append_ibm-ac-server = " ${TMPL_COOLING}"
SYSTEMD_LINK_phosphor-cooling-type_append_ibm-ac-server = " ${@compose_list(d, 'FMT_COOLING', 'OBMC_CHASSIS_INSTANCES')}"
+FILES_phosphor-cooling-type_append_mihawk = " ${bindir}/phosphor-cooling-type"
+SYSTEMD_SERVICE_phosphor-cooling-type_append_mihawk = " ${TMPL_COOLING}"
+SYSTEMD_LINK_phosphor-cooling-type_append_mihawk = " ${@compose_list(d, 'FMT_COOLING', 'OBMC_CHASSIS_INSTANCES')}"
COOLING_ENV_FMT = "obmc/phosphor-fan/phosphor-cooling-type-{0}.conf"
SYSTEMD_ENVIRONMENT_FILE_phosphor-cooling-type_append_ibm-ac-server = " ${@compose_list(d, 'COOLING_ENV_FMT', 'OBMC_CHASSIS_INSTANCES')}"
+SYSTEMD_ENVIRONMENT_FILE_phosphor-cooling-type_append_mihawk = " ${@compose_list(d, 'COOLING_ENV_FMT', 'OBMC_CHASSIS_INSTANCES')}"
#These services are protected by the watchdog
SYSTEMD_OVERRIDE_phosphor-fan-control_witherspoon += "fan-watchdog-monitor.conf:phosphor-fan-control-init@0.service.d/fan-watchdog-monitor.conf"