Fix pldm query to prevent truncating container id

The entity instance map uses a key that combines container_id and
entity_instance. The map used was truncating the key to uint16
(EntityInstance).

Sample trace of the key/values:
 openpower-occ-control[4668]: PLDM: fetchEffecterInfo() emplace(key 0x00130000,21897)
 openpower-occ-control[4668]: PLDM: fetchEffecterInfo() emplace(key 0x00130001,21899)
 openpower-occ-control[4668]: PLDM: fetchEffecterInfo() emplace(key 0x00140000,21901)
 openpower-occ-control[4668]: PLDM: fetchEffecterInfo() emplace(key 0x00140001,21903)
 openpower-occ-control[4668]: PLDM: fetchEffecterInfo() emplace(key 0x00150000,21905)
 openpower-occ-control[4668]: PLDM: fetchEffecterInfo() emplace(key 0x00150001,21907)

This prevented resets for OCCs other than instance 0 / 1.

Tested on Everest HW

Change-Id: I58c3bdd398ea99e3eeaebfe5f4474507ec8b767e
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
diff --git a/pldm.cpp b/pldm.cpp
index 43b86ab..28236c3 100644
--- a/pldm.cpp
+++ b/pldm.cpp
@@ -246,7 +246,7 @@
         return;
     }
 
-    std::map<EntityInstance, EffecterID> entityInstMap{};
+    std::map<uint32_t, EffecterID> entityInstMap{};
     for (auto& pdr : pdrs)
     {
         auto pdrPtr =
@@ -313,8 +313,10 @@
     if (effecterEntry == occInstanceToEffecter.end())
     {
         log<level::ERR>(
-            "pldm: Failed to find a matching effecter for OCC instance",
-            entry("OCC_INSTANCE_ID=%d", occInstanceId));
+            fmt::format(
+                "pldm: Failed to find a matching effecter for OCC instance {}",
+                occInstanceId)
+                .c_str());
 
         return;
     }