vpd-tool:Fix system VPD and its backup VPD

vpd-tool fixSystemVPD implementation to backup and restore system VPD
to and from the backup VPD if the backup VPD path is found in
vpd inventory JSON.

Test:
(Truncating the output in commit message)

===>>CASE 1: Option 6 to update new value on both backup and primary
hardware and its cache.

vpd-tool --fixSystemVPD
=============================================================
S.No  Record  Keyword  Backup Data  Primary Data    Data Mismatch
1     UTIL    D0       0x01         0x01            NO
============================================================

>> Enter the new value to update on both primary & backup. Value should be in ASCII or in HEX(prefixed with 0x) : 0x00

busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/base_op_panel_blyth com.ibm.ipzvpd.VSBK D0
ay 1 0

busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard com.ibm.ipzvpd.UTIL D0
ay 1 0

===>>CASE 2: Option 4 to update primary with backup data

vpd-tool -w -O /system/chassis/motherboard -R LXR0 -K LX -V 0x333435363738
Data updated successfully

vpd-tool --fixSystemVPD
=================================================================================
S.No  Record  Keyword  Backup Data            Primary Data           Data Mismatch
6     LXR0    LX       0x310004010030007b     0x333435363738007b     YES
=================================================================================

Enter 4 => If you choose the data on backup as the right value : 4

busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard com.ibm.ipzvpd.LXR0 LX
ay 8 49 0 4 1 0 48 0 123

===>>CASE 3: Option 5 to update backup with primary value
vpd-tool -w -O /system/chassis/motherboard/base_op_panel_blyth -R VSBK -K FC -V "abcd"
Data updated successfully

vpd-tool --fixSystemVPD
=================================================================================
S.No  Record  Keyword  Backup Data            Primary Data           Data Mismatch
7     VCEN    FC       0x616263642d303031     0x324534412d303031     YES
=================================================================================

Enter 5 => If you choose the data on primary as the right value : 5

busctl get-property xyz.openbmc_project.Inventory.Manager /xyz/openbmc_project/inventory/system/chassis/motherboard/base_op_panel_blyth com.ibm.ipzvpd.VSBK FC
ay 8 50 69 52 65 45 48 48 49

===>>CASE 4: Option 2 to update all mismatching keywords with its primary data

vpd-tool -w -O /system/chassis/motherboard/base_op_panel_blyth -R VSBK -K FC -V "abcd"
Data updated successfully

vpd-tool -w -O /system/chassis/motherboard/base_op_panel_blyth -R VSBK -K D0 -V "abcd"
Data updated successfully

vpd-tool --fixSystemVPD
=================================================================================
S.No  Record  Keyword  Backup Data            Primary Data           Data Mismatch
=================================================================================
1     UTIL    D0       0x61                   0x01                   YES
-------------------------------------------------------------------------------
7     VCEN    FC       0x616263642d303031     0x324534412d303031     YES
=================================================================================

Enter 2 => If you choose the data on primary for all mismatching record-keyword pairs : 2

Data updated successfully for all mismatching record-keyword pairs by choosing their corresponding data from primary VPD.

vpd-tool -r -O /system/chassis/motherboard/base_op_panel_blyth -R VSBK -K FC
{
    "/system/chassis/motherboard/base_op_panel_blyth": {
        "FC": "2E4A-001"
    }
}
vpd-tool -r -O /system/chassis/motherboard/base_op_panel_blyth -R VSBK -K D0
{
    "/system/chassis/motherboard/base_op_panel_blyth": {
        "D0": "0x01"
    }
}

===>>CASE 5: Option 1

vpd-tool -w -O /system/chassis/motherboard -R UTIL -K D0 -V "abcd"
Data updated successfully
vpd-tool -w -O /system/chassis/motherboard -R UTIL -K D1 -V "abcd"
Data updated successfully

vpd-tool --fixSystemVPD
=================================================================================
S.No  Record  Keyword  Backup Data            Primary Data           Data Mismatch
=================================================================================
1     UTIL    D0       0x01                   0x61                   YES
-------------------------------------------------------------------------------
2     UTIL    D1       0x00                   0x61                   YES
=================================================================================

Enter 1 => If you choose the data on backup for all mismatching record-keyword pairs: 1

Data updated successfully for all mismatching record-keyword pairs by choosing their corresponding data from backup. Exit successfully.

vpd-tool -r -O /system/chassis/motherboard  -R UTIL -K D0
{
    "/system/chassis/motherboard": {
        "D0": "0x01"
    }
}
vpd-tool -r -O /system/chassis/motherboard  -R UTIL -K D1
{
    "/system/chassis/motherboard": {
        "D1": "0x00"
    }
}

Change-Id: I0cfa5c869d4c44d2dd74916b5284fa2ad9b4f398
Signed-off-by: Priyanga Ramasamy <priyanga24@in.ibm.com>
diff --git a/vpd_tool_impl.hpp b/vpd_tool_impl.hpp
index 11e6ef8..25f07af 100644
--- a/vpd_tool_impl.hpp
+++ b/vpd_tool_impl.hpp
@@ -12,7 +12,7 @@
 
 // <S.no, Record, Keyword, D-Bus value, HW value, Data mismatch>
 using SystemCriticalData =
-    std::vector<std::tuple<int, std::string, std::string, std::string,
+    std::vector<std::tuple<uint8_t, std::string, std::string, std::string,
                            std::string, std::string>>;
 
 class VpdTool
@@ -141,8 +141,10 @@
      * @brief Parse through the options to fix system VPD
      *
      * @param[in] json - Inventory JSON
+     * @param[in] backupEEPROMPath - Backup VPD path
      */
-    void parseSVPDOptions(const nlohmann::json& json);
+    void parseSVPDOptions(const nlohmann::json& json,
+                          const std::string& backupEEPROMPath);
 
     /**
      * @brief List of user options that can be used to fix system VPD keywords.
@@ -279,6 +281,19 @@
     int cleanSystemVPD();
 
     /**
+     * @brief Fix system VPD and its backup VPD
+     * API is triggerred if the backup of system VPD has to be taken in a
+     * hardware VPD. User can use the --fixSystemVPD option to restore the
+     * keywords in backup VPD and/or system VPD.
+     *
+     * @param[in] backupEepromPath - Backup VPD path
+     * @param[in] backupInvPath - Backup inventory path
+     * @return returncode
+     */
+    int fixSystemBackupVPD(const std::string& backupEepromPath,
+                           const std::string& backupInvPath);
+
+    /**
      * @brief Constructor
      * Constructor is called during the
      * object instantiation for dumpInventory option and