pfr-manager: update pfr cpld error codes

Add support to update the cpld error codes in new platform.

Remove the IBB and OBB watchdog expired events as they are no longer
reported from CPLD.

Tested:
Update BMC firmware with mismatched SVN.
POST: https://<BMC_IP>/redfish/v1/UpdateService/
      with <BMC_Update_Capsule> binary file
Update failed and event log received.
Command: GET: https://<BMC_IP>/redfish/v1/Systems/system/LogServices/
              EventLog/Entries
Response:
 {
            "@odata.id": "/redfish/v1/Systems/system/LogServices/
             EventLog/Entries/1621435142_1",
            "@odata.type": "#LogEntry.v1_4_0.LogEntry",
            "Created": "2021-05-19T14:39:02+00:00",
            "EntryType": "Event",
            "Id": "1621435142_1",
            "Message": "Firmware resiliency error. Error reason:
             Firmware update failed(MinorCode:0x02).",
            "MessageArgs": [
                "Firmware update failed(MinorCode:0x02)"
            ],
            "MessageId": "OpenBMC.0.1.FirmwareResiliencyError",
            "Name": "System Event Log Entry",
            "Severity": "Critical"
        },

Signed-off-by: Chalapathi Venkataramashetty <chalapathix.venkataramashetty@intel.com>
Change-Id: I406cb50695bd77b1beddb0788677af3657dca334