Fix for mismatch error codes between CPLD and SEL

Issue: Minor error code values do not match between CPLD and SEL

Fix: Due to logical OR, function to read minor error code was not
getting a chance to execute. Modifed the condition so that left hand
side and right hand side of AND executes.

Tested:

1.Minor code at 0x09 is 01.
Command: i2cdump -y -r 0x00-0x7f 4 0x38
Response:
No size specified (using byte-data access)
     0  1  2  3  4  5  6  7  8  9  a  b  c  d  e  f    0123456789abcdef
00: de 01 00 0e 02 09 05 04 02 01 20 00 00 00 00 09    ??.??????? ....?

2. Verified the minor code in Redfish.
Command:
GET: https://<BMC_IP>/redfish/v1/Systems/system/LogServices/EventLog/
                     Entries
Response:
{
      "@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/
                    Entries/1589118595_2",
      "@odata.type": "#LogEntry.v1_4_0.LogEntry",
      "Created": "2020-05-10T13:49:55+00:00",
      "EntryType": "Event",
      "Id": "1589118595_2",
      "Message": "BIOS firmware resiliency error. Error reason: BIOS
                  image authentication failed(MinorCode:0x01).",
      "MessageArgs": [
        "BIOS image authentication failed(MinorCode:0x01)"
      ],
      "MessageId": "OpenBMC.0.1.BIOSFirmwareResiliencyError",
      "Name": "System Event Log Entry",
      "Severity": "Critical"
}

Signed-off-by: Chalapathi <chalapathix.venkataramashetty@intel.com>
Change-Id: Ia5c13b25633b5d029fa6b57f444693430cde49d6
1 file changed