Power: add events for power rail and voltage regulator faults
Define two events: PowerRailFault and VoltageRegulatorFault.
These can be used for power rail / pgood failure and voltage regulator
reported failures respectively.
Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
Change-Id: I5f0391fa8a513b04d57e2f8d932b4b8023773283
diff --git a/gen/xyz/openbmc_project/State/Power/meson.build b/gen/xyz/openbmc_project/State/Power/meson.build
new file mode 100644
index 0000000..34d81a9
--- /dev/null
+++ b/gen/xyz/openbmc_project/State/Power/meson.build
@@ -0,0 +1,26 @@
+# Generated file; do not modify.
+
+sdbusplus_current_path = 'xyz/openbmc_project/State/Power'
+
+generated_sources += custom_target(
+ 'xyz/openbmc_project/State/Power__cpp'.underscorify(),
+ input: ['../../../../../yaml/xyz/openbmc_project/State/Power.events.yaml'],
+ output: ['event.cpp', 'event.hpp'],
+ depend_files: sdbusplusplus_depfiles,
+ command: [
+ sdbuspp_gen_meson_prog,
+ '--command',
+ 'cpp',
+ '--output',
+ meson.current_build_dir(),
+ '--tool',
+ sdbusplusplus_prog,
+ '--directory',
+ meson.current_source_dir() / '../../../../../yaml',
+ 'xyz/openbmc_project/State/Power',
+ ],
+ install: should_generate_cpp,
+ install_dir: [false, get_option('includedir') / sdbusplus_current_path],
+ build_by_default: should_generate_cpp,
+)
+
diff --git a/gen/xyz/openbmc_project/State/meson.build b/gen/xyz/openbmc_project/State/meson.build
index e5f2a81..b318619 100644
--- a/gen/xyz/openbmc_project/State/meson.build
+++ b/gen/xyz/openbmc_project/State/meson.build
@@ -9,6 +9,7 @@
subdir('Host')
subdir('Leak')
subdir('OperatingSystem')
+subdir('Power')
subdir('PowerOnHours')
subdir('SMC')
subdir('ScheduledHostTransition')
@@ -184,6 +185,50 @@
)
generated_markdown += custom_target(
+ 'xyz/openbmc_project/State/Power__markdown'.underscorify(),
+ input: ['../../../../yaml/xyz/openbmc_project/State/Power.events.yaml'],
+ output: ['Power.md'],
+ depend_files: sdbusplusplus_depfiles,
+ command: [
+ sdbuspp_gen_meson_prog,
+ '--command',
+ 'markdown',
+ '--output',
+ meson.current_build_dir(),
+ '--tool',
+ sdbusplusplus_prog,
+ '--directory',
+ meson.current_source_dir() / '../../../../yaml',
+ 'xyz/openbmc_project/State/Power',
+ ],
+ install: should_generate_markdown,
+ install_dir: [inst_markdown_dir / sdbusplus_current_path],
+ build_by_default: should_generate_markdown,
+)
+
+generated_registry += custom_target(
+ 'xyz/openbmc_project/State/Power__registry'.underscorify(),
+ input: ['../../../../yaml/xyz/openbmc_project/State/Power.events.yaml'],
+ output: ['Power.json'],
+ depend_files: sdbusplusplus_depfiles,
+ command: [
+ sdbuspp_gen_meson_prog,
+ '--command',
+ 'registry',
+ '--output',
+ meson.current_build_dir(),
+ '--tool',
+ sdbusplusplus_prog,
+ '--directory',
+ meson.current_source_dir() / '../../../../yaml',
+ 'xyz/openbmc_project/State/Power',
+ ],
+ install: should_generate_registry,
+ install_dir: [inst_registry_dir / sdbusplus_current_path],
+ build_by_default: should_generate_registry,
+)
+
+generated_markdown += custom_target(
'xyz/openbmc_project/State/PowerOnHours__markdown'.underscorify(),
input: [
'../../../../yaml/xyz/openbmc_project/State/PowerOnHours.interface.yaml',
diff --git a/yaml/xyz/openbmc_project/State/Power.events.yaml b/yaml/xyz/openbmc_project/State/Power.events.yaml
new file mode 100644
index 0000000..0e61ed7
--- /dev/null
+++ b/yaml/xyz/openbmc_project/State/Power.events.yaml
@@ -0,0 +1,34 @@
+version: 1.0.0
+
+errors:
+ - name: PowerRailFault
+ severity: error
+ metadata:
+ - name: PowerRail
+ type: object_path
+ primary: true
+ description: The name or identifier of the power rail.
+ - name: FailureData
+ type: string
+ description: An [optional] set of additional failure data.
+ en:
+ description: A fault has been detected on a power rail.
+ message: A fault has been detected on power rail '{Rail}'.
+ errno: EIO
+
+ - name: VoltageRegulatorFault
+ severity: error
+ metadata:
+ - name: VoltageRegulator
+ type: object_path
+ primary: true
+ description: The name or identifier of the voltage regulator.
+ - name: FailureData
+ type: string
+ description: An [optional] set of additional failure data.
+ en:
+ description: A fault has been detected from a voltage regulator.
+ message:
+ A fault has been detected on voltage regulator
+ '{VoltageRegulator}'
+ errno: EIO