Control.Power.Mode: Add new power management modes

New modes:
- Balanced Performance
- Efficiency Favor Performance
- Efficiency Favor Power
Also reordered the enums (alphabetical)

Modes were added to the Redfish ComputerSystem v1.22 schema

Change-Id: I70ba36a6afb13896d812eeb822752020b03d9673
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
1 file changed
tree: 089fc81b1d93f65ab50f171ca5de02f039c45cc7
  1. gen/
  2. subprojects/
  3. yaml/
  4. .gitignore
  5. .markdownlint.yaml
  6. .prettierrc.yaml
  7. .shellcheck
  8. LICENSE
  9. meson.build
  10. meson.options
  11. OWNERS
  12. README.md
  13. requirements.md
README.md

phosphor-dbus-interfaces

YAML descriptors of standard D-Bus interfaces. The format is described by the sdbusplus binding generation tool sdbus++.

Before defining a new D-Bus interface or modifying an existing one, please read through the documented set of the common requirements and expectations.

Building

This project can be built with meson. The typical meson workflow is: meson builddir && ninja -C builddir.

The meson files used to handle the YAML files are automatically generated and found under the gen subdirectory. When adding or removing YAML files, this must be regenerated. This can be done with the helper script found in the gen subdirectory: cd gen && ./regenerate-meson.

Configuration

Only the xyz/openbmc_project and org/freedesktop interfaces are built by default. Other interfaces can be enabled by meson options:

  • com/ibm - -Ddata_com_ibm=true
  • org/open_power - -Ddata_org_open_power=true

Example: meson builddir -Ddata_com_ibm=true && ninja -C builddir

References