Add Host selector yaml configuration

Host selector interface is used to keep the position
of the host selector HW switch as a property.
This host selector position value decides which host
or bmc is currently selected in a multihost bmc system
so that the power and reset button events are
routed to the currently selected host or bmc's power control events.

Tested:
  It's tested in Facebook multi-host Yosemitev2 system,
including in the Front panel with its selector button.

Signed-off-by: Manikandan Elumalai <manikandan.hcl.ers.epl@gmail.com>
Change-Id: I18b4bd779c467d7ddc5045c5380d93c1b8a73b74
4 files changed
tree: d0d46f54e312e7415f94df5d83a6004e31da096c
  1. gen/
  2. subprojects/
  3. yaml/
  4. .gitignore
  5. .shellcheck
  6. LICENSE
  7. MAINTAINERS
  8. meson.build
  9. meson_options.txt
  10. README.md
README.md

phosphor-dbus-interfaces

YAML descriptors of standard D-Bus interfaces. The format is described by the sdbusplus binding generation tool sdbus++.

Building

This project can be built with meson. The typical meson workflow is: meson builddir && ninja -C builddir.

The meson files used to handle the YAML files are automatically generated and found under the gen subdirectory. When adding or removing YAML files, this must be regenerated. This can be done with the helper script found in the gen subdirectory: cd gen && ./regenerate-meson.

Configuration

Only the xyz/openbmc_project interfaces are built by default. Other interfaces can be enabled by meson options:

  • com/ibm - -Ddata_com_ibm=true
  • org/open_power - -Ddata_org_open_power=true

Example: meson builddir -Ddata_com_ibm=true && ninja -C builddir

References