commit | 2b1e8c6b3513d94c0b000f040ea54448c8fab7b8 | [log] [tgz] |
---|---|---|
author | Brandon Wyman <v2cib530@us.ibm.com> | Fri Mar 24 16:00:59 2017 -0500 |
committer | Brandon Wyman <bjwyman@gmail.com> | Thu Mar 30 15:47:19 2017 -0500 |
tree | 87b745ec6a21877c9b1e696c1599e2f735f9fc5f | |
parent | d0e67b3c4f34a59fb0337e4b51fd8ab66f6e21a1 [diff] |
New YAML definition for CoolingType properties. Add property AirCooled that will be set to true if cooled by air (fans). Add property WaterCooled that will be set to true if cooled by water. Change-Id: I816b41a7205ede1583718ae1ec8e27031ba392c8 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>