docs:monitor: Fill in the power_off_config attribute details

The `power_off_config` attribute contains a list of power off rules
based on the monitoring state of the fans configured. These power off
rules can perform different system power off types to protect a system
that is not able to provide enough cooling due to missing or
nonfunctional fans.

Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Change-Id: Idabaa3a2bb626d3b9048506ed23cd50fb9377f00
diff --git a/docs/monitor/power_off_config.md b/docs/monitor/power_off_config.md
index 9ae40d7..dc0e3d7 100644
--- a/docs/monitor/power_off_config.md
+++ b/docs/monitor/power_off_config.md
@@ -1,9 +1,74 @@
 # power_off_config
 
 ## Description
-
+A list of power off rules based on the monitoring state of the fans configured. These power off rules can perform different system power off types to protect a system that is not able to provide enough cooling due to a number of missing or nonfunctional fans.
 
 ## Attribute Value(s)
+* `type` - ["hard", "soft", "epow"]
+  * "hard" - Perform a hard shutdown that immediately powers off the system.
+  * "soft" - Perform an orderly shutdown requesting that the host OS power off
+  the system.
+  * "epow" - Sets the thermal alert D-Bus property that a power off is imminent
+  after a `service_mode_delay` amount of time passes.
+* `cause` - ["missing_fan_frus", "nonfunc_fan_rotors"]
+  * "missing_fan_frus" - Power off due to missing fan enclosures
+  * "nonfunc_fan_rotors" - Power off due to nonfunctional fan
+  rotors([`sensors`](sensors.md))
+* `count` - integer
+  * Number of the configured `cause` instances to begin the power off `type`
 
+### "hard" & "soft" `type` power offs
+* `delay` - integer
+  * Time(in seconds) to delay performing the power off after `count` instances
+  of the `cause` criteria is met.
+* `state` - ["at_pgood", "runtime"] (Optional)
+  * "at_pgood" - At system pgood, the power off rule becomes valid. A power off
+  rule of *"at_pgood"* can halt a system power on if the conditions are met.
+  * "runtime" - At system runtime, the power off rule becomes valid. A power
+  off rule of *"runtime"* only goes into affect after the system reaches
+  runtime. (Default)
+
+### "epow" `type` power offs
+* `service_mode_delay` - integer
+  * Time(in seconds) given before the thermal alert D-Bus property is set to
+  indicate that a power off is imminent if the `count` instances of the `cause`
+  criteria still exists. This timer is canceled when the `count` instances of
+  the `cause` is not longer met.
+* `meltdown_delay` - integer
+  * Time(in seconds) before a hard power off occurs after the
+  `service_mode_delay` timer expires. This timer can not be canceled once
+  started.
 
 ## Example
+<pre><code>
+{
+  "fault_handling": [
+    {
+      "num_nonfunc_rotors_before_error": 1,
+      <b><i>"power_off_config": [
+        {
+          "type": "hard",
+          "cause": "missing_fan_frus",
+          "count": 1,
+          "delay": 25,
+          "state": "at_pgood"
+        },
+        {
+          "type": "soft",
+          "cause": "nonfunc_fan_rotors",
+          "count": 2,
+          "delay": 30,
+          "state": "runtime"
+        },
+        {
+          "type": "epow",
+          "cause": "nonfunc_fan_rotors",
+          "count": 3,
+          "service_mode_delay": 300,
+          "meltdown_delay": 300
+        }
+      ]</i></b>
+    }
+  ]
+}
+</code></pre>