control:Bonnell: Increase deviation value
Increase Bonnell's lower deviation setting from 18% to 22%. This is
necessary because the lower end for the outlet rotors was raised by an
earlier commit that modified the factor and offset values so that a
different fan type can be supported.
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: Ie68e6f2a60109b566328ab2bac1cdeb029f255b2
diff --git a/monitor/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Bonnell/config.json b/monitor/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Bonnell/config.json
index 6d1427c..8900913 100644
--- a/monitor/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Bonnell/config.json
+++ b/monitor/config_files/p10bmc/com.ibm.Hardware.Chassis.Model.Bonnell/config.json
@@ -4,7 +4,7 @@
"inventory": "/system/chassis/motherboard/fan0",
"method": "count",
"count_interval": 1,
- "deviation": 18,
+ "deviation": 22,
"upper_deviation": 40,
"num_sensors_nonfunc_for_fan_nonfunc": 0,
"monitor_start_delay": 30,
@@ -30,7 +30,7 @@
"inventory": "/system/chassis/motherboard/fan1",
"method": "count",
"count_interval": 1,
- "deviation": 18,
+ "deviation": 22,
"upper_deviation": 40,
"num_sensors_nonfunc_for_fan_nonfunc": 0,
"monitor_start_delay": 30,