control: Remove setting target = poweron target at startup

After constructing the zone objects, the fan objects are created with
their current target set to what's on dbus. This is then read and set on
the zone as the fan(s) are added to their configured zone. Setting the
target to the configured poweron target of the zone should not be done
by default to ensure the zone is set to whatever the target is of its
contained fan(s).

Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Change-Id: I13bb83e6c06c4220e56c5574ee26c607074c261a