monitor: journal message for fan Actual Speed wrong
Problem: Actual speed is formatted with the wrong format type.
Solution: By using the format library, it is not necessary to specify a
format for the result, and speed is correctly displayed.
Tested: Ran with simulation.
In terminal connected to simiulator:
systemctl disable
phosphor-dbus-monitor.service obmcutil poweron
changed the fan speed in /sys/class/hwmon/hwmon9/fan1_target using an
echo command:
echo 8000 > fan1_target
After jrnl showed the fan had been disabled, setting fan to
nonfunctional showed expected speed:
"Setting fan /system/chassis/motherboard/fan5 to nonfunctional Sensor:
/xyz/openbmc_project/sensors/fan_tach/fan5_0 Actual speed: 8000.0 Target speed:
11200"
Changed the fan speed back:
echo 11200 > fan1_target
journal entry for setting fan back to functional was seen.
"Setting fan /system/chassis/motherboard/fan2 back to functional"