Convert a log entry into a SEL record
Check the DBUS logging entry for callout associations, if there
is a mapping between the inventory path and sensor number then
populate the SEL record. Otherwise log a SEL against the sytem
event sensor.
Resolves openbmc/openbmc#1516
Change-Id: I516bdac70cf39260af1744a9cdb118d763009bd5
Signed-off-by: Tom Joseph <tomjoseph@in.ibm.com>
diff --git a/selutility.hpp b/selutility.hpp
index 83ff0fd..573e89b 100644
--- a/selutility.hpp
+++ b/selutility.hpp
@@ -43,6 +43,15 @@
uint8_t eventData3; //!< Event Data 3.
} __attribute__((packed));
+/** @brief Convert logging entry to SEL
+ *
+ * @param[in] objPath - DBUS object path of the logging entry.
+ *
+ * @return On success return the response of Get SEL entry command.
+ */
+GetSELEntryResponse convertLogEntrytoSEL(const std::string& objPath);
+
+
namespace internal
{