sensorcommands:Platform Event Message command corrected

Add support to check the incoming channel type and update the
generatorID based on requester slave address.

Add support to check for valid evmRev and Sensor Type.

Tested:
Command: ipmitool  -I lanplus -H <BMC_IP> -U root -P 0penBmc raw 0x04
0x02 0x04 0x6a 0xcd 0xf6 0x6b 0xed 0x0f
Response: Unable to send RAW command (channel=0x0 netfn=0x4 lun=0x0
cmd=0x2 rsp=0xcc): Invalid data field in request

Command: ipmitool  -I lanplus -H <BMC_IP> -U root -P 0penBmc raw 0x04
0x02 0x54 0x6a 0xcd 0xf6 0x6b 0xed 0x0f
Response: Unable to send RAW command (channel=0x0 netfn=0x4 lun=0x0
cmd=0x2 rsp=0xcc): Invalid data field in request

Ported From: https://gerrit.openbmc-project.xyz/c/openbmc/intel-ipmi-oem/+/44255

Signed-off-by: Chalapathi Venkataramashetty <chalapathix.venkataramashetty@intel.com>
Change-Id: Ibb93d09777f5a7c515d45a4aa910c657d503d9ce
Signed-off-by: Willy Tu <wltu@google.com>