PEL:Procedure to correct system VPD issues
This commit adds a new callout procedure "BMC0007" to correct
* system backplane VPD mismatch between hardware value and
backed up value.
* system backplane data being blank on both hardware and in
backup.
Test:
Tested that newly added callout procedure has been picked
when there is a system VPD mismatch and when the data is
blank.
peltool -i 0x500024AB
{
"Private Header": {
"Section Version": "1",
"Sub-section type": "0",
"Created by": "0x4000",
"Created at": "12/05/2022 05:58:47",
"Committed at": "12/05/2022 05:58:47",
"Creator Subsystem": "BMC",
"CSSVER": "",
"Platform Log Id": "0x500024AB",
"Entry Id": "0x500024AB",
"BMC Event Log Id": "314"
},
"User Header": {
"Section Version": "1",
"Sub-section type": "0",
"Log Committed by": "0x2000",
"Subsystem": "CEC Hardware - VPD Interface",
"Event Scope": "Entire Platform",
"Event Severity": "Predictive Error",
"Event Type": "Not Applicable",
"Action Flags": [
"Service Action Required",
"Report Externally",
"HMC Call Home"
],
"Host Transmission": "Not Sent",
"HMC Transmission": "Not Sent"
},
"Primary SRC": {
"Section Version": "1",
"Sub-section type": "1",
"Created by": "0x4000",
"SRC Version": "0x02",
"SRC Format": "0x55",
"Virtual Progress SRC": "False",
"I5/OS Service Event Bit": "False",
"Hypervisor Dump Initiated":"False",
"Backplane CCIN": "2E2D",
"Terminate FW Error": "False",
"Deconfigured": "False",
"Guarded": "False",
"Error Details": {
"Message": "A system VPD restoration error"
"occurred."
},
"Valid Word Count": "0x09",
"Reference Code": "BD554008",
"Hex Word 2": "00080055",
"Hex Word 3": "2E2D0010",
"Hex Word 4": "00000000",
"Hex Word 5": "00000000",
"Hex Word 6": "00000000",
"Hex Word 7": "00000000",
"Hex Word 8": "00000000",
"Hex Word 9": "00000000",
"Callout Section": {
"Callout Count": "2",
"Callouts": [{
"FRU Type": "Normal Hardware FRU",
"Priority": "Mandatory, replace all with this"
"type as a unit",
"Location Code": "U78DA.ND0.WZS007H-P0",
"Part Number": "02WG676",
"CCIN": "2E2D",
"Serial Number": "YF33UF19Y007"
}, {
"FRU Type": "Maintenance Procedure Required",
"Priority": "Mandatory, replace all with this"
"type as a unit",
"Procedure": "BMC0007"
}]
}
},
"Extended User Header": {
"Section Version": "1",
"Sub-section type": "0",
"Created by": "0x2000",
"Reporting Machine Type": "9105-22B",
"Reporting Serial Number": "1392BE0",
"FW Released Ver": "",
"FW SubSys Version": "fw1040.00-1.2",
"Common Ref Time": "00/00/0000 00:00:00",
"Symptom Id Len": "20",
"Symptom Id": "BD554008_2E2D0010"
},
"Failing MTMS": {
"Section Version": "1",
"Sub-section type": "0",
"Created by": "0x2000",
"Machine Type Model": "9105-22B",
"Serial Number": "1392BE0"
},
"User Data 0": {
"Section Version": "1",
"Sub-section type": "1",
"Created by": "0x2000",
"BMCLoad": "0.22 0.41 0.33",
"BMCState": "Ready",
"BMCUptime": "0y 0d 0h 13m 6s",
"BootState": "Unspecified",
"ChassisState": "Off",
"FW Version ID": "fw1040.00-1.2-2-g1859836242-dirty",
"HostState": "Off",
"System IM": "50001001"
},
"User Data 1": {
"Section Version": "1",
"Sub-section type": "1",
"Created by": "0x2000",
"CALLOUT_INVENTORY_PATH": "/xyz/openbmc_project/inventory/system"
"/chassis/motherboard",
"DESCRIPTION": "VPD data mismatch on cache and hardware for"
"record: LXR0 and keyword: LX",
"Value on Cache: ": "0x31 0x0 0x4 0x1 0x0 0x30 0x0 0x71 ",
"Value read from EEPROM: ": "0x64 0x65 0x4 0x1 0x0 0x30 0x0 0x71 "
}
}
Signed-off-by: Priyanga Ramasamy <priyanga24@in.ibm.com>
Change-Id: I738542d55781538285cb3747461929195cbd6d48
diff --git a/extensions/openpower-pels/registry/message_registry.json b/extensions/openpower-pels/registry/message_registry.json
index 904d255..5255f8d 100644
--- a/extensions/openpower-pels/registry/message_registry.json
+++ b/extensions/openpower-pels/registry/message_registry.json
@@ -4700,6 +4700,17 @@
"Words6To9": {}
},
+ "Callouts": [
+ {
+ "CalloutList": [
+ {
+ "Priority": "high",
+ "Procedure": "system_vpd_correction"
+ }
+ ]
+ }
+ ],
+
"Documentation": {
"Description": "System VPD restore failed",
"Message": "A system VPD restoration error occurred.",
@@ -4809,7 +4820,10 @@
"Callouts": [
{
"CalloutList": [
- { "Priority": "high", "Procedure": "bmc_code" }
+ {
+ "Priority": "high",
+ "Procedure": "system_vpd_correction"
+ }
]
}
],