PEL: Removed severity from OCC OpenFailure PEL
The OpenFailure PEL was being set to predictive severity.
These errors can happen when a system hits a processor checkpoint. There
should already be another error logged for the checkstop, so if the code
hits this condition it will be logged as Notice/Informational.
Also made some changes to add journal traces to other occ-control PELs.
Tested on Rainier.
Change-Id: I320a0758344718e8d1fff478c9c561063ec070e6
Signed-off-by: Chris Cain <cjcain@us.ibm.com>
diff --git a/extensions/openpower-pels/registry/message_registry.json b/extensions/openpower-pels/registry/message_registry.json
index b49aa21..2f28b1f 100644
--- a/extensions/openpower-pels/registry/message_registry.json
+++ b/extensions/openpower-pels/registry/message_registry.json
@@ -901,6 +901,9 @@
"The number of OCCs detected by the BMC does not match the number of OCCs detected by the OCC.",
"The BMC requests that the OCC reset."
]
+ },
+ "JournalCapture": {
+ "NumLines": 60
}
},
@@ -922,6 +925,14 @@
"The BMC detected that the OCC was in safe state for one minute while active.",
"The BMC requests that the OCC reset."
]
+ },
+ "JournalCapture": {
+ "Sections": [
+ {
+ "SyslogID": "openpower-occ-control",
+ "NumLines": 80
+ }
+ ]
}
},
@@ -943,6 +954,9 @@
"The BMC failed to communicate with the OCC and retried three times.",
"The BMC requests that the OCC reset."
]
+ },
+ "JournalCapture": {
+ "NumLines": 80
}
},
@@ -950,7 +964,6 @@
"Name": "org.open_power.OCC.Device.Error.OpenFailure",
"Subsystem": "cec_chip_iface",
"ComponentID": "0x2600",
- "Severity": "predictive",
"SRC": {
"ReasonCode": "0x2684",
@@ -963,6 +976,9 @@
"Notes": [
"There was a failure trying to open an OCC device driver file"
]
+ },
+ "JournalCapture": {
+ "NumLines": 80
}
},
@@ -993,7 +1009,7 @@
]
},
"JournalCapture": {
- "NumLines": 40
+ "NumLines": 100
}
},